2022 Good Quality Rapid Gel Clot Test - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G52 – Bioendo


Product Detail

Related Video

Feedback (2)

To meet the customers' over-expected satisfaction , we have our strong team to provide our best overall service which includes marketing, sales, designing, production, quality controlling, packing, warehousing and logistics for LAL Turbidimetric detection, Gel Clot Method, Bacterial Endotoxin Test Sop, If you are interested in any of our products, please feel free to contact us for more details. We hope to cooperate with more friends from all over the world.
2022 Good Quality Rapid Gel Clot Test - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G52 – Bioendo Detail:

Gel Clot Method Lyophilized Amebocyte Lysate Multi-test Vial G52 series

1. Product Information

Gel Clot method Lyophilized Amebocyte Lysate Multi-test Vial is the Lyophilized Amebocyte Lysate reagent which select and use gel clot technique to detect endotoxin or pyrogen.

As the widespread method, gel-clot test for endotoxin is simple and does not require specific and expensive instrument. Bioendo provides Gel Clot Lyophilized Amebocyte Lysate reagent in 5.2ml per vial.

2. Product Parameters

Sensitivity range: 0.03EU/ml, 0.06EU/ml, 0.125EU/ml, 0.25EU/ml, 0.5 EU/ml 

3. Product Application

End-product endotoxin (pyrogen) qualification, waterfor injection endotoxin assay, raw material endotoxin testing or endotoxinlevel monitoring during manufacturing process for pharmaceutical companies ormedical devices manufacturers.

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from lysate of amebocytes (white blood cells) from the horseshoe crab.

Gel clot method LAL assay, reconstituted lysate reagent get at least 50 tests per vial:
Catalog Number Sensitivity (EU/ml or IU/ml) ml/vial Tests/Vial Vials/Pack
G520030 0.03 5.2 50 10
G520060 0.06 5.2 50 10
G520125 0.125 5.2 50 10
G520250 0.25 5.2 50 10
G520500 0.5 5.2 50 10

Product condition

The Lyophilized Amebocyte Lysate reagent sensitivity and the Control Standard Endotoxin potency are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte reagent kits come with product instruction, Certificate of Analysis, MSDS.

 

What is the difference between single test and multiple test?

● Single test: reconstitute the single test lysate reagent by BET water in the glass vial or glass ampoule.

● Multi-test: reconstitute the lysate reagent with BET water, and then add marked amount of lysate reagent following COA to the reaction tube or well plate for use. There is no difference in the sample pre-processing procedure; according to the amount of testing used, the sample size used for a single test is larger than the sample size used for multiple tests.

 

Why the most selected gel clot assay kit G52:

1. Multi test reagent for endotoxin detection in the applications of certain samples’ endotoxin detection.

2. G52 series of Gel clot assay multi test glass vial no need sophisticated microplate reader. Procedure of incubation by water bath or dry heat incubator.

3. High end quality of endotoxin free tube (<0.005EU/ml) and High quality of pyrogen free tips (<0.005EU/ml) as the guaranteed consumables to ensure the correct result.

Related products in the endotoxin test assay:
Water for Bacterial Endotoxins Test (BET),  Recommend TRW50 or TRW100
Endotoxin free glass tube ( dilution tube ),  Recommend T1310018 and T107540
Pyrogen free tips,  Recommend PT25096 or PT100096
Pipettor, Recommend PSB0220
Test Tube Rack,
Incubation Instrument (Water Bath or Dry Heat Incubator ), Recommend Dry Heat Incubator TAL-M2
Vortex Mixter, Recommend VXH.
Control Standard Endotoxin, CSE10V.

Product detail pictures:

2022 Good Quality Rapid Gel Clot Test - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G52 – Bioendo detail pictures

2022 Good Quality Rapid Gel Clot Test - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G52 – Bioendo detail pictures

2022 Good Quality Rapid Gel Clot Test - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G52 – Bioendo detail pictures

2022 Good Quality Rapid Gel Clot Test - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G52 – Bioendo detail pictures

2022 Good Quality Rapid Gel Clot Test - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G52 – Bioendo detail pictures


Related Product Guide:

With this motto in mind, we have become one of the most technologically innovative, cost-efficient, and price-competitive manufacturers for 2022 Good Quality Rapid Gel Clot Test - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G52 – Bioendo , The product will supply to all over the world, such as: Morocco, Stuttgart, Luxembourg, Profession, Devoting are always fundamental to our mission. We've got always been in line with serving customers, creating value management objectives and adhering to the sincerity, dedication, persistent management idea.
  • The factory can meet continuously developing economic and market needs, so that their products are widely recognized and trusted, and that's why we chose this company.
    5 Stars By Eleanore from Finland - 2018.12.14 15:26
    The customer service staff is very patient and has a positive and progressive attitude to our interest, so that we can have a comprehensive understanding of the product and finally we reached an agreement, thanks!
    5 Stars By Fanny from US - 2017.12.09 14:01

    Leave Your Messages

    Related products

    • 100% Original 200ul Pipette tip - Pyrogen-free Centrifuge Tube – Bioendo

      100% Original 200ul Pipette tip - Pyrogen-free...

      Pyrogen-free Centrifuge Tube   Product features: * Pyrogen-free Centrifuge tube is made from virgin polypropylene to meet the general requirements of the laboratory. * Pyrogen-free, Endotoxin level <0.005EU/ml * High strength non-toxic materials * Printed clear graduations with marking area * Gamma Radiation Sterilized * 50ml Maximum RCF is 18000g, 15ml Maximum RCF is 12000g * DNase/RNase free * Autoclavable * Temperature range is -20°C to 121°C * Leak-proof * Cap 50% longer ideal for avo...

    • Factory Cheap Hot limulus amebocyte - Endotoxin Assay and (1,3)-ß-D-glucan assay software – Bioendo

      Factory Cheap Hot limulus amebocyte - Endotoxi...

      Endotoxin and (1,3)-ß-D-glucan assay software 1. Product information Endotoxin and (1,3)-ß-D-glucan assay software is a powerful kinetic data analysis software,which gives the user data acquisition and processing of the maximum flexibility. Features: • Apply to Endotoxin assay,(1,3)-ß-D-glucan assay and ELISA data analysis • With standard version and clinical diagnostic version for the different user groups. • Data could be output transitions and connected to the LIS system. • Customizabl...

    • Online Exporter Endotoxin Detection System - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo

      Online Exporter Endotoxin Detection System - B...

      Beta-glucans Blocker for Blocking Beta Glucan Pathway 1. Product information There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Gl...

    • OEM/ODM Supplier Kit LAL - Eight-channel Mechanical Pipette – Bioendo

      OEM/ODM Supplier Kit LAL - Eight-channel Mecha...

      Eight-Channel Mechanical Pipettor 1. Product information All multi-channel mechanical pipettor have been quality tested according to ISO8655-2:2002 with calibration certificate. The quality control involves gravimetric testing of each pipette with distilled water at 22℃. The multichannel mechanical pipettor is idea for the detectionof bacterial endotoxin lal endotoxin testing by kinetic turbidimetric andkinetic chromogenic method. - Eight-Channel Mechanical Pipettor is available for stand...

    • Factory Outlets Endotoxin LAL Method - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo

      Factory Outlets Endotoxin LAL Method - Beta-gl...

      Beta-glucans Blocker for Blocking Beta Glucan Pathway 1. Product information There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Gl...

    • Factory wholesale Depyrogenated microplate - Rapid Gel Clot single test kit – Bioendo

      Factory wholesale Depyrogenated microplate - R...

      Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit) 1. Product Information Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures ...