Our advantages are lower prices,dynamic sales team,specialized QC,strong factories,high quality products and services for LAL gel clot test, Kinetic Turbidimetric LAL kit for endotoxin detection, Bacterial Endotoxin Test Calculation, Create Values,Serving Customer!" would be the purpose we pursue. We sincerely hope that all clients will build long-lasting and mutually effective cooperation with us.In the event you wish to get extra facts about our enterprise, Be sure to get in touch with with us now.
8 Year Exporter Endotoxin LAL Test - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo Detail:

Beta-glucans Blocker for Blocking Beta Glucan Pathway

1. Product information

There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Glucan, such as cellulose, using beta-glucans blocker would be a good idea to block the β-1,3-Glucan interference to endotoxin and LAL reagent reaction.

2. Product parameter

Endotoxin level less than 0.005EU/ml

3. Product features and application

Substitute LAL Reagent Water to reconstitute LAL reagent, blocks the beta-glucan mediates factor G pathway and insure the LAL reagent only reacts to endotoxin. For the test samples that has the (1,3)- β-D-Glucan contamination.

Catalog No.

Description

Note

Package

BH10

50mM Tris buffer, pH7.0, 10ml/vial

Used to dilute highly acidic or basic samples.

10 vials/pack

BH50

50mM Tris buffer, pH7.0, 50ml/vial

 Used to dilute highly acidic or basic samples.  10 vials/pack

BY10

10mM Magnesium Buffer, 10ml/vial

Used to overcome chelation effect.

 10 vials/pack

BT10

β-glucans blocker, 10ml/vial

Used to block β-glucan interference in Amebocyte Lysate endotoxin reactions.

 10 vials/pack

PBS50

PBS buffer endotoxin-free, 50ml/vial

Use to wash sample containers, or adjust pH

 10 vials/pack

PBS500

PBS buffer endotoxin-free, 500ml/vial

 

1 vial

Product Condition

The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis.


Product detail pictures:

8 Year Exporter Endotoxin LAL Test - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo detail pictures

8 Year Exporter Endotoxin LAL Test - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo detail pictures

8 Year Exporter Endotoxin LAL Test - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo detail pictures

8 Year Exporter Endotoxin LAL Test - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo detail pictures


Related Product Guide:

Our improvement depends on the superior equipment, excellent talents and continuously strengthened technology forces for 8 Year Exporter Endotoxin LAL Test - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo , The product will supply to all over the world, such as: Denver, Nepal, Venezuela, All our products are exported to clients in the UK, Germany, France, Spain, the USA, Canada, Iran, Iraq, the Middle East and Africa. Our products are well welcomed by our customers for the high quality, competitive prices and the most favorable styles. We hope to establish business relationship with all customers and bring more beautifu colors for the life.
  • The quality of the products is very good, especially in the details, can be seen that the company work actively to satisfy customer's interest, a nice supplier.
    5 Stars By Karl from Moldova - 2017.07.07 13:00
    Product quality is good, quality assurance system is complete, every link can inquire and solve the problem timely!
    5 Stars By Jean from Somalia - 2017.12.09 14:01

    Leave Your Messages

    Related products

    • 2022 Good Quality TAL assay kit - Pyrogen-free Centrifuge Tube – Bioendo

      2022 Good Quality TAL assay kit - Pyrogen-free...

      Pyrogen-free Centrifuge Tube   Product features: * Pyrogen-free Centrifuge tube is made from virgin polypropylene to meet the general requirements of the laboratory. * Pyrogen-free, Endotoxin level <0.005EU/ml * High strength non-toxic materials * Printed clear graduations with marking area * Gamma Radiation Sterilized * 50ml Maximum RCF is 18000g, 15ml Maximum RCF is 12000g * DNase/RNase free * Autoclavable * Temperature range is -20°C to 121°C * Leak-proof * Cap 50% longer ideal for avo...

    • Factory Cheap Hot limulus amebocyte - Rapid Gel Clot single test kit – Bioendo

      Factory Cheap Hot limulus amebocyte - Rapid Ge...

      Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit) 1. Product Information Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures ...

    • Wholesale Price China Kinetic chromogenic TAL Assay - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo

      Wholesale Price China Kinetic chromogenic TAL A...

      Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) 1. Product Information In Bioendo KC Endotoxin Test Kit, Amebocyte Lysate is co-lyophilized with chromogenic substrate. Therefore, bacterial endotoxin could be quantified based on the chromogenic reaction. The assay is strong resistance to interference, and has advantages of kinetic turbidimetric and end-point chromogenic method. Bioendo Endotoxin Test Kit contains Chromogenic Amebocyte Lysate, Reconstitution Buffer, CSE, Water for BE...

    • Reasonable price Chromogenic LAL Endotoxin Assay Kit - Endpoint Chromogenic Kit EC64405 – Bioendo

      Reasonable price Chromogenic LAL Endotoxin Assa...

      End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) 1. Product Information End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is conducted by adding a colorless artificial peptide substrate solution into mixture of Lyophilized Amebocyte Lysate and test sample after a certain incubation period. If test sample contain endotoxin, a yellow color will develop in the 96 well microplate. Its absorbance (λmax = 405nm) is related to the endotoxin concentration. Endotoxin ...

    • 2022 Good Quality TAL assay kit - Single-Channel Mechanical Pipettor – Bioendo

      2022 Good Quality TAL assay kit - Single-Chann...

      Single-Channel Mechanical Pipettor   1. Product Information Single channel mechanical pipette is ideal tool to support endotoxin detection with Lyophilized Amebocyte Lysate which covers gel-clot technique, kinetic turbidimetric technique, kinetic chromogenic technique, and end-point chromogenic technique. All pipettors are produced by following ISO8655 – 2:2002. The quality control involves gravimetric testing of each pipette with distilled water at 22℃.   2. Product Features: - ...

    • OEM/ODM China Dry heat sterilizer validation by ECV - Eight-channel Mechanical Pipette – Bioendo

      OEM/ODM China Dry heat sterilizer validation by...

      Eight-Channel Mechanical Pipettor 1. Product information All multi-channel mechanical pipettor have been quality tested according to ISO8655-2:2002 with calibration certificate. The quality control involves gravimetric testing of each pipette with distilled water at 22℃. The multichannel mechanical pipettor is idea for the detectionof bacterial endotoxin lal endotoxin testing by kinetic turbidimetric andkinetic chromogenic method. - Eight-Channel Mechanical Pipettor is available for stand...