8 Year Exporter Endotoxin LAL Test - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo


Product Detail

Related Video

Feedback (2)

We will make every effort to be outstanding and perfect, and accelerate our steps for standing in the rank of international top-grade and high-tech enterprises for Endotoxin Lps, Pyrogen Free Tube, Endosafe LAL Kit, On account of superior quality and competitive price , we will be the market leader, please don’t hesitate to contact us by phone or email, if you are interested in any of our products.
8 Year Exporter Endotoxin LAL Test - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo Detail:

Beta-glucans Blocker for Blocking Beta Glucan Pathway

1. Product information

There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Glucan, such as cellulose, using beta-glucans blocker would be a good idea to block the β-1,3-Glucan interference to endotoxin and LAL reagent reaction.

2. Product parameter

Endotoxin level less than 0.005EU/ml

3. Product features and application

Substitute LAL Reagent Water to reconstitute LAL reagent, blocks the beta-glucan mediates factor G pathway and insure the LAL reagent only reacts to endotoxin. For the test samples that has the (1,3)- β-D-Glucan contamination.

Catalog No.

Description

Note

Package

BH10

50mM Tris buffer, pH7.0, 10ml/vial

Used to dilute highly acidic or basic samples.

10 vials/pack

BH50

50mM Tris buffer, pH7.0, 50ml/vial

 Used to dilute highly acidic or basic samples.  10 vials/pack

BY10

10mM Magnesium Buffer, 10ml/vial

Used to overcome chelation effect.

 10 vials/pack

BT10

β-glucans blocker, 10ml/vial

Used to block β-glucan interference in Amebocyte Lysate endotoxin reactions.

 10 vials/pack

PBS50

PBS buffer endotoxin-free, 50ml/vial

Use to wash sample containers, or adjust pH

 10 vials/pack

PBS500

PBS buffer endotoxin-free, 500ml/vial

 

1 vial

Product Condition

The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis.


Product detail pictures:

8 Year Exporter Endotoxin LAL Test - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo detail pictures

8 Year Exporter Endotoxin LAL Test - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo detail pictures

8 Year Exporter Endotoxin LAL Test - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo detail pictures

8 Year Exporter Endotoxin LAL Test - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo detail pictures


Related Product Guide:

We aim to find out high quality disfigurement in the generation and provide the most effective services to domestic and abroad clients wholeheartedly for 8 Year Exporter Endotoxin LAL Test - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo , The product will supply to all over the world, such as: Bogota, Bangladesh, Brunei, We'll initiate the second phase of our development strategy. Our company regards "reasonable prices, efficient production time and good after-sales service" as our tenet. If you are interested in any of our products and solutions or would like to discuss a custom order, make sure you feel free to contact us. We've been looking forward to forming successful business relationships with new clients around the world in the near future.
  • The company account manager has a wealth of industry knowledge and experience, he could provide appropriate program according our needs and speak English fluently.
    5 Stars By Irene from Korea - 2017.10.27 12:12
    The sales manager has a good English level and skilled professional knowledge, we have a good communication. He is a warm and cheerful man, we have a pleasant cooperation and we became very good friends in private.
    5 Stars By Agustin from Oman - 2017.11.29 11:09

    Leave Your Messages

    Related products

    • Wholesale Price Endotoxin challenge vial - Pyrogen-free (Endotoxin-free) Tris Buffer – Bioendo

      Wholesale Price Endotoxin challenge vial - Pyr...

      Pyrogen-free (Endotoxin-free) Tris Buffer 1. Product information Buffers must be validated to be free of detectable endotoxin andinterfering factors. Using 50mM Tris buffer to dissolve or dilute the testsamples is a convenient way to adjust the reaction pH. Pyrogen-free (endotoxin-free) Tris buffer to adjusting the pH of the LAL endotoxin test samples. Lyophilized Amebocyte Lysate testing microbiology detection of endotoxin by horseshoecrab blue blood lysate require certain conditions. The ...

    • Factory source Advantage Of LAL Test - Rapid Gel Clot single test kit – Bioendo

      Factory source Advantage Of LAL Test - Rapid G...

      Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit) 1. Product Information Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures ...

    • Manufacturer for LAL reagent manufacturer - Rapid Gel Clot single test kit – Bioendo

      Manufacturer for LAL reagent manufacturer - Ra...

      Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit) 1. Product Information Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures ...

    • Good Quality endotoxin testing - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo

      Good Quality endotoxin testing - Pyrogen-free ...

      Pyrogen-free Microplates, 96 Well Plate Strips and pyrogen free Reagent Reservoir 1. Product information These pyrogen-free 96-well plates (endotoxin-free microplates, pyrogen-free reservoir, cell culture plate, endotoxin-free plates) is used in the End-point Chromogenic Lyophilized Amebocyte Lysate Assay, Kinetic Chromogenic Lyophilized Amebocyte Lysate Assay and Kinetic Turbidimetric  endotoxin test assay. The microplates and resevoirs contain endotoxins <0.005 EU/ml endotoxin. Catalog...

    • Hot-selling Kinetic chromogenic LAL test kit - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo

      Hot-selling Kinetic chromogenic LAL test kit -...

       Micro KC Endotoxin Test Kit (Micro Kinetic Chromogenic Endotoxin Assay) The Bioendo MicroKC Endotoxin Test Kit (Micro Kinetic Chromogenic Endotoxin Assay), which adopts the micro-technical kinetic chromogenic method, is equipped with a special customized 96-well microplates, which can be used in the endotoxin test of microbial detection system Elx808IULALXH and other conventional endotoxin detection equipment to realize the micro-kinetic chromogenic endotoxin detection. The micro KC kit mee...

    • Reasonable price Turbidimetric LAL assay - Kinetic Turbidimetric Amebocyte Lysate Vial – Bioendo

      Reasonable price Turbidimetric LAL assay - Kin...

      Kinetic Turbidimetric Amebocyte Lysate Vial 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration.  2. Product Parame...