We normally follow the basic principle "Quality Initial, Prestige Supreme". We've been fully committed to offering our consumers with competitively priced good quality merchandise, prompt delivery and professional support for Kinetic chromogenic LAL Assay, Endpoint Chromogenic Endotoxin test kit, Endotoxin Producing Bacteria, We warmly welcome your participation according to mutual rewards during the around long term.
Best quality LAL chromogenic detection - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo Detail:

Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay)

1. Product Information

In Bioendo KC Endotoxin Test Kit, Amebocyte Lysate is co-lyophilized with chromogenic substrate. Therefore, bacterial endotoxin could be quantified based on the chromogenic reaction. The assay is strong resistance to interference, and has advantages of kinetic turbidimetric and end-point chromogenic method. Bioendo Endotoxin Test Kit contains Chromogenic Amebocyte Lysate, Reconstitution Buffer, CSE, Water for BET. Endotoxin detection with Kinetic Chromogenic method requires a kinetic incubating microplate reader such as ELx808IULALXH.

 

2. Product Parameter

Assay Range: 0.005 – 50EU/ml; 0.001 – 10EU/ml

Catalog No.

Description

Kit Contents

Sensitivity EU/ml

KC5028

Bioendo™ KC Endotoxin Test Kit (Kinetic Chromogenic Assay),

1300 Tests/Kit

50 Chromogenic Amebocyte Lysate,

2.8ml (26 Tests/Vial);

50 Reconstitution Buffer, 3.0ml/vial; 

10CSE; 

0.005-5EU/ml

KC5028S

0.001-10EU/ml

KC0828

Bioendo™ KC Endotoxin Test Kit (Kinetic Chromogenic Assay),

 208 Tests/Kit

8 Chromogenic Amebocyte Lysate,

2.8ml (26 Tests/Vial);

8 Reconstitution Buffer, 3.0ml/vial;

4 CSE; 

2 Water for BET, 50ml/vial;

0.005-5EU/ml

KC0828S

0.001-10EU/ml

KC5017

Bioendo™ KC Endotoxin Test Kit (Kinetic Chromogenic Assay),

800 Tests/Kit

50 Chromogenic Amebocyte Lysate,

1.7ml (16 Tests/Vial);

50 Reconstitution Buffer, 2.0ml/vial; 

10CSE; 

0.005-5 EU/ml

KC5017S

0.001-10 EU/m

KC0817

Bioendo™ KC Endotoxin Test Kit (Kinetic Chromogenic Assay),

128 Tests/kit

8 Kinetic Chromogenic Amebocyte Lysate, 

1.7ml (16 Tests/vial);

8 Reconstitution Buffer, 2.0ml/vial;

4 CSE;

2 Water for BET, 50ml/vial;

0.005-5 EU/ml

KC0817S

0.001-10 EU/ml

 

3. Product Feature and Application

BioendoTM KC Endotoxin Test Kit (Kinetic Chromogenic Assay) features strong resistance to interference, and has advantages of kinetic turbidimetric and end-point chromogenic method. It is especially suitable for endotoxin detection of biological samples like vaccine, antibody, protein, nucleic acid, etc.

Note:

Lyophilized Amebocyte Lysate reagent manufactured by Bioendo is made from amebocyte lysate from the horseshoe crab (Tachypleus tridentatus).

Product Condition:

The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis. 

The kinetic chromogenic endotoxin test kit have to choose the microplate reader with 405nm filters.


Product detail pictures:

Best quality LAL chromogenic detection - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo detail pictures

Best quality LAL chromogenic detection - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo detail pictures

Best quality LAL chromogenic detection - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo detail pictures

Best quality LAL chromogenic detection - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo detail pictures

Best quality LAL chromogenic detection - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo detail pictures


Related Product Guide:

With reliable excellent approach, great name and ideal consumer services, the series of products and solutions produced by our company are exported to many countries and regions for Best quality LAL chromogenic detection - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo , The product will supply to all over the world, such as: Bahrain, Estonia, Belize, We always adhere to follow the honesty, mutual benefit, common development, after years of development and the tireless efforts of all staff, now has perfect export system, diversified logistics solutions, thorough meet customer shipping, air transport, international express and logistics services. Elaborate one-stop sourcing platform for our customers!
  • Products and services are very good, our leader is very satisfied with this procurement, it is better than we expected,
    5 Stars By Ellen from Lisbon - 2017.10.13 10:47
    The company's products can meet our diverse needs, and the price is cheap, the most important is that the quality is also very nice.
    5 Stars By Penelope from USA - 2018.12.25 12:43

    Leave Your Messages

    Related products

    • Top Suppliers Dry Heat Sterilizer Validation - Rapid Gel Clot 10 Samples Kit – Bioendo

      Top Suppliers Dry Heat Sterilizer Validation -...

      Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit) 1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedure...

    • High Quality for Bioendo - Kinetic Incubating Microplate Reader ELX808IULALXH  – Bioendo

      High Quality for Bioendo - Kinetic Incubating ...

      Kinetic Incubating Microplate Reader 1. Product information Kinetic Incubating Microplate Reader Elx808 is a multifunctional kinetic reader designed for bacterial endotoxin assay, fungi (1,3)-ß-D-glucan assay and ELISA assays. The reader is a highly accurate, easy to use instrument for kinetic turbidimetric LAL/TAL assay, kinetic chromogenic LAL test and endpoint chromogenic LAL assay.  Compare to kinetic incubating tube reader,the microplate reader is more efficient and is possible to be sc...

    • Chinese wholesale LAL test kit - Compact Modular Dry Heat Incubator – Bioendo

      Chinese wholesale LAL test kit - Compact Modul...

      Dry Heat Incubator 1. Product description: Dry Heat Incubator TAL-M2 is amicroprocessor-controlled device, high precision of temperature control, samplepreparation parallelism, as an alternative to the traditional water bathdevice. It is recommended to use in the gel clot TAL endotoxin assay. And it can be widely used in various other application includes the pharmaceutical, chemical, food safety, environment, quality inspection. TAL-M2 includes 2 heating modules. TAL- M2 A Dry bath incubat...

    • OEM Customized Endotixins - Single-Channel Mechanical Pipettor – Bioendo

      OEM Customized Endotixins - Single-Channel Mec...

      Single-Channel Mechanical Pipettor   1. Product Information Single channel mechanical pipette is ideal tool to support endotoxin detection with Lyophilized Amebocyte Lysate which covers gel-clot technique, kinetic turbidimetric technique, kinetic chromogenic technique, and end-point chromogenic technique. All pipettors are produced by following ISO8655 – 2:2002. The quality control involves gravimetric testing of each pipette with distilled water at 22℃.   2. Product Features: - ...

    • Quality Inspection for Endotoxin Kits - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo

      Quality Inspection for Endotoxin Kits - Beta-g...

      Beta-glucans Blocker for Blocking Beta Glucan Pathway 1. Product information There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Gl...

    • 2022 China New Design Kinetic chromogenic TAL test - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo

      2022 China New Design Kinetic chromogenic TAL t...

      Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) 1. Product Information In Bioendo KC Endotoxin Test Kit, Amebocyte Lysate is co-lyophilized with chromogenic substrate. Therefore, bacterial endotoxin could be quantified based on the chromogenic reaction. The assay is strong resistance to interference, and has advantages of kinetic turbidimetric and end-point chromogenic method. Bioendo Endotoxin Test Kit contains Chromogenic Amebocyte Lysate, Reconstitution Buffer, CSE, Water for BE...