China OEM Data Logger For Oven Validation - Rapid Gel Clot 10 Samples Kit – Bioendo


Product Detail

Related Video

Feedback (2)

We consistently execute our spirit of ''Innovation bringing progress, Highly-quality ensuring subsistence, Administration advertising and marketing gain, Credit history attracting buyers for Endotoxin Free Tube, Endotoxin Free Tubes, bacterial endotoxin test, We will supply best quality, the most market competitive price, for every new and old customers with the most perfect green services.
China OEM Data Logger For Oven Validation - Rapid Gel Clot 10 Samples Kit – Bioendo Detail:

Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit)
1. Product Information

Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedures are very convenient, additional experimental equipment are required. It is a convenient and rapid way to detect endotoxin in especial suitable for water or dialysate.

20190819091605_48802

2. Product Parameter

Sensitivity Range: 0.03EU/ml, 0.06EU/ml, 0.125EU/ml, 0.25EU/ml, 0.5EU/ml

10 sample tests in the kit. 

Assay time: less than 30 minutes

3. Product Application

Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate as well as do quickly endotoxin detection in life science research.

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from amebocyte lysate derived blood of horseshoe crab.

Catalog No.

Description

Kit Contents

Sensitivity

EU/ml

Reaction Time

minutes

RG10025003

BioendoTM Rapid Gel Clot Endotoxin Assay Kit, 10 Samples Kit

10 SPL Tubes;

10 PPC Tubes;

10 Endotoxin-free Sample Bottles;

10 Packs of (3pcs Transfer Pipettes)

0.03

≤60

RG10025006

0.06

≤60

RG100250125

0.125

≤45

RG10025025

0.25

≤30

RG10025050

0.5

≤30

Kit configuration: 
Bioendo Rapid Gel Clot Endotoxin Assay Kit contains: 
10 SPL Tube, 10 PPC Tube, 10 Endotoxin-free Sample Bottle, 10 Pack of Transfer Pipette 3 pieces.
Simple and convenient procedure in the dilution of control standard endotoxin. Endotoxin free sample container and pyrogen free transfer pipette is required, Sophisticated instruments are required, recommend Bioendo Dry heat incubator TAL-MT use in the procedure of incubation.   

Product detail pictures:

China OEM Data Logger For Oven Validation - Rapid Gel Clot 10 Samples Kit – Bioendo detail pictures

China OEM Data Logger For Oven Validation - Rapid Gel Clot 10 Samples Kit – Bioendo detail pictures

China OEM Data Logger For Oven Validation - Rapid Gel Clot 10 Samples Kit – Bioendo detail pictures

China OEM Data Logger For Oven Validation - Rapid Gel Clot 10 Samples Kit – Bioendo detail pictures


Related Product Guide:

With a positive and progressive attitude to customer's interest, our enterprise continually improves our products excellent to meet the wants of customers and further focuses on safety, reliability, environmental requirements, and innovation of China OEM Data Logger For Oven Validation - Rapid Gel Clot 10 Samples Kit – Bioendo , The product will supply to all over the world, such as: Rome, Angola, Pakistan, We warmly welcome domestic and overseas customers to visit our company and have business talk. Our company always insists on the principle of "good quality, reasonable price, the first-class service". We have been willing to build long-term, friendly and mutually beneficial cooperation with you.
  • The company can think what our think, the urgency of urgency to act in the interests of our position, can be said this is a responsible company, we had a happy cooperation!
    5 Stars By Federico Michael Di Marco from Houston - 2017.09.30 16:36
    This is a very professional and honest Chinese supplier, from now on we fell in love with the Chinese manufacturing.
    5 Stars By Erica from United States - 2017.12.31 14:53

    Leave Your Messages

    Related products

    • Wholesale Price China Kinetic chromogenic TAL Assay - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo

      Wholesale Price China Kinetic chromogenic TAL A...

      Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) 1. Product Information In Bioendo KC Endotoxin Test Kit, Amebocyte Lysate is co-lyophilized with chromogenic substrate. Therefore, bacterial endotoxin could be quantified based on the chromogenic reaction. The assay is strong resistance to interference, and has advantages of kinetic turbidimetric and end-point chromogenic method. Bioendo Endotoxin Test Kit contains Chromogenic Amebocyte Lysate, Reconstitution Buffer, CSE, Water for BE...

    • Reasonable price Depyrogenated tips - Endotoxin Assay and (1,3)-ß-D-glucan assay software – Bioendo

      Reasonable price Depyrogenated tips - Endotoxi...

      Endotoxin and (1,3)-ß-D-glucan assay software 1. Product information Endotoxin and (1,3)-ß-D-glucan assay software is a powerful kinetic data analysis software,which gives the user data acquisition and processing of the maximum flexibility. Features: • Apply to Endotoxin assay,(1,3)-ß-D-glucan assay and ELISA data analysis • With standard version and clinical diagnostic version for the different user groups. • Data could be output transitions and connected to the LIS system. • Customizabl...

    • Wholesale Price China LAL bacterial endotoxin test - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo

      Wholesale Price China LAL bacterial endotoxin t...

      Beta-glucans Blocker for Blocking Beta Glucan Pathway 1. Product information There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Gl...

    • Factory Supply Pipette tip box - Rapid Gel Clot 10 Samples Kit – Bioendo

      Factory Supply Pipette tip box - Rapid Gel Clo...

      Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit) 1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedure...

    • Super Purchasing for Endotoxin Method - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo

      Super Purchasing for Endotoxin Method - Endoto...

       Endotoxin Challenge Vials (Endotoxin Indicator)   1. Product Information The Endotoxin Challenge Vial (ECV,Endotoxin Indicator) is used in the validation of dry heat depyrogenation cycles. Endotoxin Challenge Vials are placed in the cold spots of the dry heat oven. After cycle completion, the log reduction in endotoxin levels can be determined by comparing the endotoxin levels in the baked vs not baked Endotoxin Indicators. The Endotoxin Challenge vials are designed to indicate a minimum 3...

    • Factory Cheap Hot limulus amebocyte lysate kit - Endotoxin-specific Lyophilized Amebocyte Lysate – Bioendo

      Factory Cheap Hot limulus amebocyte lysate kit ...

      Endotoxin-specific Lyophilized Amebocyte Lysate 1. Product Information Lyophilized Amebocyte Lysate extracted from horseshoe crab contains factor C pathway which reacts to endotoxin and factor G pathway which reacts to (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate contains ß-Glucan inhibitor, which will avoid false positive, result happening between factor C pathway and (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate is especially suitable for samples...