To consistently enhance the management method by virtue of the rule of "sincerely, fantastic religion and top quality are the base of business development", we extensively absorb the essence of associated goods internationally, and constantly acquire new merchandise to satisfy the needs of shoppers for Endotoxin Bacteria, Endotoxin Lipopolysaccharide, Kinetic chromogenic TAL test kit, Sincerely hope we are growing up together with our customers all over the world.
Chinese wholesale Chromogenic endotoxin assay - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo Detail:

Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay)

1. Product Information

In Bioendo KC Endotoxin Test Kit, Amebocyte Lysate is co-lyophilized with chromogenic substrate. Therefore, bacterial endotoxin could be quantified based on the chromogenic reaction. The assay is strong resistance to interference, and has advantages of kinetic turbidimetric and end-point chromogenic method. Bioendo Endotoxin Test Kit contains Chromogenic Amebocyte Lysate, Reconstitution Buffer, CSE, Water for BET. Endotoxin detection with Kinetic Chromogenic method requires a kinetic incubating microplate reader such as ELx808IULALXH.

 

2. Product Parameter

Assay Range: 0.005 – 50EU/ml; 0.001 – 10EU/ml

Catalog No.

Description

Kit Contents

Sensitivity EU/ml

KC5028

Bioendo™ KC Endotoxin Test Kit (Kinetic Chromogenic Assay),

1300 Tests/Kit

50 Chromogenic Amebocyte Lysate,

2.8ml (26 Tests/Vial);

50 Reconstitution Buffer, 3.0ml/vial; 

10CSE; 

0.005-5EU/ml

KC5028S

0.001-10EU/ml

KC0828

Bioendo™ KC Endotoxin Test Kit (Kinetic Chromogenic Assay),

 208 Tests/Kit

8 Chromogenic Amebocyte Lysate,

2.8ml (26 Tests/Vial);

8 Reconstitution Buffer, 3.0ml/vial;

4 CSE; 

2 Water for BET, 50ml/vial;

0.005-5EU/ml

KC0828S

0.001-10EU/ml

KC5017

Bioendo™ KC Endotoxin Test Kit (Kinetic Chromogenic Assay),

800 Tests/Kit

50 Chromogenic Amebocyte Lysate,

1.7ml (16 Tests/Vial);

50 Reconstitution Buffer, 2.0ml/vial; 

10CSE; 

0.005-5 EU/ml

KC5017S

0.001-10 EU/m

KC0817

Bioendo™ KC Endotoxin Test Kit (Kinetic Chromogenic Assay),

128 Tests/kit

8 Kinetic Chromogenic Amebocyte Lysate, 

1.7ml (16 Tests/vial);

8 Reconstitution Buffer, 2.0ml/vial;

4 CSE;

2 Water for BET, 50ml/vial;

0.005-5 EU/ml

KC0817S

0.001-10 EU/ml

 

3. Product Feature and Application

BioendoTM KC Endotoxin Test Kit (Kinetic Chromogenic Assay) features strong resistance to interference, and has advantages of kinetic turbidimetric and end-point chromogenic method. It is especially suitable for endotoxin detection of biological samples like vaccine, antibody, protein, nucleic acid, etc.

Note:

Lyophilized Amebocyte Lysate reagent manufactured by Bioendo is made from amebocyte lysate from the horseshoe crab (Tachypleus tridentatus).

Product Condition:

The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis. 

The kinetic chromogenic endotoxin test kit have to choose the microplate reader with 405nm filters.


Product detail pictures:

Chinese wholesale Chromogenic endotoxin assay - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo detail pictures

Chinese wholesale Chromogenic endotoxin assay - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo detail pictures

Chinese wholesale Chromogenic endotoxin assay - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo detail pictures

Chinese wholesale Chromogenic endotoxin assay - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo detail pictures

Chinese wholesale Chromogenic endotoxin assay - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo detail pictures


Related Product Guide:

Our primary objective is always to offer our clients a serious and responsible small business relationship, offering personalized attention to all of them for Chinese wholesale Chromogenic endotoxin assay - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo , The product will supply to all over the world, such as: Melbourne, Turin, Melbourne, We pay high attention to customer service, and cherish every customer. We've maintained a strong reputation in the industry for many years. We are honest and work on building a long-term relationship with our customers.
  • Managers are visionary, they have the idea of "mutual benefits, continuous improvement and innovation", we have a pleasant conversation and Cooperation.
    5 Stars By Austin Helman from Jeddah - 2017.04.28 15:45
    Good quality and fast delivery, it's very nice. Some products have a little bit problem, but the supplier replaced timely, overall, we are satisfied.
    5 Stars By Louise from Pakistan - 2018.06.21 17:11

    Leave Your Messages

    Related products

    • Wholesale Price BET Water - Rapid Gel Clot single test kit – Bioendo

      Wholesale Price BET Water - Rapid Gel Clot sin...

      Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit) 1. Product Information Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures ...

    • 2022 wholesale price Kinetic Turbidimetric vs Kinetic Chromogenic - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo

      2022 wholesale price Kinetic Turbidimetric vs K...

       Micro KC Endotoxin Test Kit (Micro Kinetic Chromogenic Endotoxin Assay) The Bioendo MicroKC Endotoxin Test Kit (Micro Kinetic Chromogenic Endotoxin Assay), which adopts the micro-technical kinetic chromogenic method, is equipped with a special customized 96-well microplates, which can be used in the endotoxin test of microbial detection system Elx808IULALXH and other conventional endotoxin detection equipment to realize the micro-kinetic chromogenic endotoxin detection. The micro KC kit mee...

    • Hot-selling Pipette tip supplier - Rapid Gel Clot 10 Samples Kit – Bioendo

      Hot-selling Pipette tip supplier - Rapid Gel C...

      Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit) 1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedure...

    • Factory source Endotoxin LAL Assay - LAL Reagent Water (Water for Bacterial Endotoxins Test) – Bioendo

      Factory source Endotoxin LAL Assay - LAL Reage...

      LAL Reagent Water ( Water for Bacterial Endotoxins Test / Water for BET / TAL Reagnt Water )  1. Product Information LAL Reagent Water (Water for Bacterial Endotoxins Test or BET Water or Water for BET )is specially processed super-purified endotoxin free water is used for Endotoxin test. Its endotoxin concentration is less than 0.005 EU/ml. Various packages, such as 2ml, 10ml, 50ml, 100ml and 500ml per unit, are provided for users’ convenience. LAL Reagent Water (Water for BET) could...

    • Massive Selection for Endotoxin Cleaning - Endotoxin-free Glass Test Tubes – Bioendo

      Massive Selection for Endotoxin Cleaning - End...

      Endotoxin-free Glass Test Tubes   1. Product Information Endotoxin-free glass test tubes contain less than 0.005EU/ml endotoxin. Catalog number T107505 and T107540  are recommended for use as reaction tubes in gel clot and end-point chromogenic assays. Catalog number T1310018 and T1310005 is recommended for dilution of endotoxin standards and test samples. T1050005C is a special designed short endotoxin reaction tube that allows the pipette tips reaches the tube bottom. T087565 is used ...

    • Wholesale Price China LAL bacterial endotoxin test - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo

      Wholesale Price China LAL bacterial endotoxin t...

      Beta-glucans Blocker for Blocking Beta Glucan Pathway 1. Product information There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Gl...