Excellent quality Depyrogenated pipette tips - Rapid Gel Clot 10 Samples Kit – Bioendo


Product Detail

Related Video

Feedback (2)

Our pursuit and firm aim should be to "Always fulfill our buyer requirements". We carry on to produce and structure top-quality excellent solutions for equally our aged and new consumers and accomplish a win-win prospect for our consumers as well as us for Endotoxin Detection Method, Depyrogenated tips box, depyrogenation is a 3-log reduction in endotoxin content, Any interest, make sure you really feel free to get hold of us. We're searching forward to forming prosperous enterprise interactions with new purchasers across the earth within the near upcoming.
Excellent quality Depyrogenated pipette tips - Rapid Gel Clot 10 Samples Kit – Bioendo Detail:

Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit)
1. Product Information

Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedures are very convenient, additional experimental equipment are required. It is a convenient and rapid way to detect endotoxin in especial suitable for water or dialysate.

20190819091605_48802

2. Product Parameter

Sensitivity Range: 0.03EU/ml, 0.06EU/ml, 0.125EU/ml, 0.25EU/ml, 0.5EU/ml

10 sample tests in the kit. 

Assay time: less than 30 minutes

3. Product Application

Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate as well as do quickly endotoxin detection in life science research.

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from amebocyte lysate derived blood of horseshoe crab.

Catalog No.

Description

Kit Contents

Sensitivity

EU/ml

Reaction Time

minutes

RG10025003

BioendoTM Rapid Gel Clot Endotoxin Assay Kit, 10 Samples Kit

10 SPL Tubes;

10 PPC Tubes;

10 Endotoxin-free Sample Bottles;

10 Packs of (3pcs Transfer Pipettes)

0.03

≤60

RG10025006

0.06

≤60

RG100250125

0.125

≤45

RG10025025

0.25

≤30

RG10025050

0.5

≤30

Kit configuration: 
Bioendo Rapid Gel Clot Endotoxin Assay Kit contains: 
10 SPL Tube, 10 PPC Tube, 10 Endotoxin-free Sample Bottle, 10 Pack of Transfer Pipette 3 pieces.
Simple and convenient procedure in the dilution of control standard endotoxin. Endotoxin free sample container and pyrogen free transfer pipette is required, Sophisticated instruments are required, recommend Bioendo Dry heat incubator TAL-MT use in the procedure of incubation.   

Product detail pictures:

Excellent quality Depyrogenated pipette tips - Rapid Gel Clot 10 Samples Kit – Bioendo detail pictures

Excellent quality Depyrogenated pipette tips - Rapid Gel Clot 10 Samples Kit – Bioendo detail pictures

Excellent quality Depyrogenated pipette tips - Rapid Gel Clot 10 Samples Kit – Bioendo detail pictures

Excellent quality Depyrogenated pipette tips - Rapid Gel Clot 10 Samples Kit – Bioendo detail pictures


Related Product Guide:

Our growth depends to the superior products ,great talents and repeatedly strengthened technology forces for Excellent quality Depyrogenated pipette tips - Rapid Gel Clot 10 Samples Kit – Bioendo , The product will supply to all over the world, such as: Palestine, Maldives, Jeddah, Based on experienced engineers, all orders for drawing-based or sample-based processing are welcomed. We have now won a good reputation for outstanding customer service among our overseas customers. We will continue to try the best to supply you good quality products and solutions and the best service. We've been looking forward to serving you.
  • We have been appreciated the Chinese manufacturing, this time also did not let us disappoint,good job!
    5 Stars By Gail from Roman - 2018.06.21 17:11
    This company can be well to meet our needs on product quantity and delivery time, so we always choose them when we have procurement requirements.
    5 Stars By David Eagleson from Roman - 2017.11.01 17:04

    Leave Your Messages

    Related products

    • OEM Customized Endotixins - Rapid Gel Clot single test kit – Bioendo

      OEM Customized Endotixins - Rapid Gel Clot sin...

      Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit) 1. Product Information Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures ...

    • New Fashion Design for Bacterial Endotoxin Test Method Validation Protocol - Depyrogenated Sample Bottles ( Endotoxin Free ) – Bioendo

      New Fashion Design for Bacterial Endotoxin Test...

      Depyrogenated Sample Container 1. Product information We offer various of low endotoxin, pyrogen free accessories products,includes Water for Bacterial Endotoxins Test, pyrogen-free test tubes, pyrogen-free pipettor tips, microplates and sample bottles for your conveniences. High quality depyrogenated low endotoxin pyrogen free products insure the success of your experiments. Depyrogenated (Endotoxin Free) Sample container(endotoxin free bottle, pyrogen free bottle, pyrogen free sample bot...

    • Wholesale Price BET Water - Single-Channel Mechanical Pipettor – Bioendo

      Wholesale Price BET Water - Single-Channel Mec...

      Single-Channel Mechanical Pipettor   1. Product Information Single channel mechanical pipette is ideal tool to support endotoxin detection with Lyophilized Amebocyte Lysate which covers gel-clot technique, kinetic turbidimetric technique, kinetic chromogenic technique, and end-point chromogenic technique. All pipettors are produced by following ISO8655 – 2:2002. The quality control involves gravimetric testing of each pipette with distilled water at 22℃.   2. Product Features: - ...

    • 2022 High quality LAL gel clot test - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo

      2022 High quality LAL gel clot test - Gel Clot...

      Gel Clot Lyophilized Amebocyte Lysate Single Test Kit  (Glass Ampoule G01) 1. Product Information Gel Clot Lyophilized Amebocyte Lysate Single Test in ampoule Contain endotoxin-specific Amebocyte Lysate which includes beta-glucan inhibitor in the formulation and will not react to beta-glucan. For our Single Test in glass ampoule, you could add sample to the glass ampoules directly. This means you don’t need to reconstitute Amebocyte Lysate in advance, and you will decide how many tests ...

    • Good Quality endotoxin testing - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo

      Good Quality endotoxin testing - Pyrogen-free ...

      Pyrogen-free Microplates, 96 Well Plate Strips and pyrogen free Reagent Reservoir 1. Product information These pyrogen-free 96-well plates (endotoxin-free microplates, pyrogen-free reservoir, cell culture plate, endotoxin-free plates) is used in the End-point Chromogenic Lyophilized Amebocyte Lysate Assay, Kinetic Chromogenic Lyophilized Amebocyte Lysate Assay and Kinetic Turbidimetric  endotoxin test assay. The microplates and resevoirs contain endotoxins <0.005 EU/ml endotoxin. Catalog...

    • Reliable Supplier Endotoxin Detection Assay - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo

      Reliable Supplier Endotoxin Detection Assay - ...

      Beta-glucans Blocker for Blocking Beta Glucan Pathway 1. Product information There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Gl...