Excellent quality Turbidimetric endotoxin assays - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo


Product Detail

Related Video

Feedback (2)

Our team through professional training. Skilled professional knowledge, strong sense of service, to meet the service needs of customers for Pyrogen free microplate, Rapid Endotoxin Detection, Endotoxin Free Microplate, With a wide range, top quality, realistic costs and good company, we are going to be your most effective company partner. We welcome new and aged clients from all walks of daily life to call us for long term small business interactions and acquiring mutual achievements!
Excellent quality Turbidimetric endotoxin assays - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo Detail:

Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay)

1. Product Introduction

Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration.
The kit contains Lyophilized Amebocyte Lysate, Control Standard Endotoxin, and Water for BET. KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) require a kinetic microplate reader such as ELx808IULALXH or a kinetic tube reader. Kinetic software is also required for calculation of the endotoxin concentration.

2. Product Parameter

Assay Range: 0.005 – 5EU/ml; 0.01 – 10EU/ml

3. Product Application

End-product endotoxin (pyrogen) qualification, Waterfor injection endotoxin assay, raw material endotoxin testing or endotoxinlevel monitoring during manufacturing process for pharmaceutical companies ormedical devices manufacturers.

Note:

Lyophilized Amebocyte Lysate reagent manufactured by Bioendo is made from amebocyte lysate from the horseshoe crab (Tachypleus tridentatus).

Catalog No.

Description

Kit Contents

Sensitivity EU/ml

KT0817

Bioendo™ KT Endotoxin Test Kit

(Kinetic Turbidimetric Assay), 128 tests/kit

8 Lyophilized Amebocyte Lysate, 1.7ml (16 Tests/vial);

8 Reconstitution Buffer, 3.0ml/vial;

4 CSE; 2 Water for BET, 50ml/vial;

0.01-10EU/ml

KT0817S

0.005-5EU/ml,

0.01-10EU/ml

KT0852

Bioendo™ KT Endotoxin Test Kit

(Kinetic Turbidimetric Assay), 400 Tests/Kit

8 Lyophilized Amebocyte Lysate, 5.2ml (50 Tests/Vial);

8 Reconstitution Buffer, 6.0ml/vial;

4 CSE; 3 Water for BET, 50ml/vial;

0.01-10EU/ml

KT0852S

0.005-5EU/ml,

0.01-10EU/ml

KT5017

Bioendo™ KT Endotoxin Test Kit

(Kinetic Turbidimetric Assay), 800 Tests/Kit

50 Lyophilized Amebocyte Lysate, 1.7ml (16 Tests/vial);

50 Reconstitution Buffer, 3.0ml/vial; 10 CSE;

0.01-10EU/ml

KT5017S

0.005-5EU/ml,

0.01-10EU/ml

KT5052

Bioendo™ KT Endotoxin Test Kit

(Kinetic Turbidimetric Assay), 2500 Tests/Kit

50 Lyophilized Amebocyte Lysate,5.2ml (50 Tests/vial);

50 Reconstitution Buffer, 6.0ml/vial; 10 CSE;

0.01-10EU/ml

KT5052S

0.005-5EU/ml,

0.01-10EU/ml

Product Condition:

The potency of Lyophilized Amebocyte Lysate and Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis, MSDS.


Product detail pictures:

Excellent quality Turbidimetric endotoxin assays - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo detail pictures

Excellent quality Turbidimetric endotoxin assays - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo detail pictures

Excellent quality Turbidimetric endotoxin assays - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo detail pictures

Excellent quality Turbidimetric endotoxin assays - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo detail pictures

Excellent quality Turbidimetric endotoxin assays - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo detail pictures


Related Product Guide:

Our company promises all buyers of the first-class products and solutions as well as most satisfying post-sale support. We warmly welcome our regular and new shoppers to join us for Excellent quality Turbidimetric endotoxin assays - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo , The product will supply to all over the world, such as: Las Vegas, Armenia, Costa Rica, We strongly believe that technology and service is our base today and quality will create our reliable walls of future. Only we have better and better quality , could we achieve our customers and ourselves, too. Welcome customers all over the word to contact us for getting further business and reliable relationships. We are always here working for your demands whenever you need.
  • Customer service staff and sales man are very patience and they all good at English, product's arrival is also very timely, a good supplier.
    5 Stars By Christine from Nigeria - 2018.10.09 19:07
    The factory workers have a good team spirit, so we received high quality products fast, in addition, the price is also appropriate, this is a very good and reliable Chinese manufacturers.
    5 Stars By Mary from Norwegian - 2018.02.21 12:14

    Leave Your Messages

    Related products

    • Hot New Products Rapid Gel Clot Endotoxin Test Kit For Water And Dialysate - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G52 – Bioendo

      Hot New Products Rapid Gel Clot Endotoxin Test ...

      Gel Clot Method Lyophilized Amebocyte Lysate Multi-test Vial G52 series 1. Product Information Gel Clot method Lyophilized Amebocyte Lysate Multi-test Vial is the Lyophilized Amebocyte Lysate reagent which select and use gel clot technique to detect endotoxin or pyrogen. As the widespread method, gel-clot test for endotoxin is simple and does not require specific and expensive instrument. Bioendo provides Gel Clot Lyophilized Amebocyte Lysate reagent in 5.2ml per vial. 2. Product Parameter...

    • Factory selling Bacterial Endotoxin Limit For API - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo

      Factory selling Bacterial Endotoxin Limit For A...

      Beta-glucans Blocker for Blocking Beta Glucan Pathway 1. Product information There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Gl...

    • Professional China bacterial endotoxin test - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo

      Professional China bacterial endotoxin test - ...

       Endotoxin Challenge Vials (Endotoxin Indicator)   1. Product Information The Endotoxin Challenge Vial (ECV,Endotoxin Indicator) is used in the validation of dry heat depyrogenation cycles. Endotoxin Challenge Vials are placed in the cold spots of the dry heat oven. After cycle completion, the log reduction in endotoxin levels can be determined by comparing the endotoxin levels in the baked vs not baked Endotoxin Indicators. The Endotoxin Challenge vials are designed to indicate a minimum 3...

    • High Quality LAL Reagent - Compact Modular Dry Heat Incubator – Bioendo

      High Quality LAL Reagent - Compact Modular Dry...

      Dry Heat Incubator 1. Product description: Dry Heat Incubator TAL-M2 is amicroprocessor-controlled device, high precision of temperature control, samplepreparation parallelism, as an alternative to the traditional water bathdevice. It is recommended to use in the gel clot TAL endotoxin assay. And it can be widely used in various other application includes the pharmaceutical, chemical, food safety, environment, quality inspection. TAL-M2 includes 2 heating modules. TAL- M2 A Dry bath incubat...

    • OEM/ODM China Rapid Endotoxin Detection - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo

      OEM/ODM China Rapid Endotoxin Detection - Beta...

      Beta-glucans Blocker for Blocking Beta Glucan Pathway 1. Product information There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Gl...

    • Manufacturing Companies for Advantages Of LAL Test - Rapid Gel Clot single test kit – Bioendo

      Manufacturing Companies for Advantages Of LAL T...

      Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit) 1. Product Information Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures ...