 Micro KC Endotoxin Test Kit (Micro Kinetic Chromogenic Endotoxin Assay)

The Bioendo MicroKC Endotoxin Test Kit (Micro Kinetic Chromogenic Endotoxin Assay), which adopts the micro-technical kinetic chromogenic method, is equipped with a special customized 96-well microplates, which can be used in the endotoxin test of microbial detection system Elx808IULALXH and other conventional endotoxin detection equipment to realize the micro-kinetic chromogenic endotoxin detection. The micro KC kit meets the requirements of the rules of Bacterial Endotoxin Test in Pharmacopoeia. Each test requires only the 25μL sample for test and 25μL of lysate reagent. The testing principle is the same as that of the traditional kinetic chromogenic method for endotoxin detection. It has strong anti-interference ability and is very suitable for endotoxins quantitative detection in parenteral drugs, vaccines, antibodies, biological preparations and so on.

Typical users:

Pharmaceutical manufacturers, medical devices manufacturers, scientific research institutions.

Ø Less dosage of sample for test , and each test only needs 25μL of samples for testing.
Ø Adopting the pharmacopoeia-approved kinetic chromogenic method technology which can meet the requirements of GMP for data integrity and traceability.
Ø High sensitivity, up to 0.005EU/ml.
Ø Strong anti-interference ability, does not require coagulogen to form a gel, and accurately quantifies bacterial endotoxins based on the color reaction.
Ø Easy to operate, complete 96 tests at one time, and the system automatically detects and analyzes in one step.
Ø High cost-effective, higher performance.
Ø Supporting 8-well plate for micro-detection

 

Technical Parameters: 

Catalog No.

Description

Kit Contents

Sensitivity EU/ml

MKC0505VS

Bioendo™ KC Endotoxin Test Kit (Micro Kinetic Chromogenic Assay), 90 Tests/Kit

5 Chromogenic Amebocyte Lysate, 0.5ml (18 Tests/Vial);

5 Reconstitution Buffer, 2.0ml/vial; 

0.005 to 5EU/ml

MKC0505V

0.01 to 10EU/ml

MKC0505AS

Bioendo™ KC Endotoxin Test Kit (Micro Kinetic Chromogenic Assay), 90 Tests/Kit

5 Chromogenic Amebocyte Lysate, 0.5ml (18 Tests/ampoule);

5 Reconstitution Buffer, 2.0ml/vial; 

0.005 to 5EU/ml

MKC0505A

0.01 to 10EU/ml

MPMC96

8 wells per strip

96 wells per microplate, 12pcs detachable strips.

 

What is the main feature of new Bioendo microKC kit?

Each test requires only the 25μL sample for test and 25μL of lysate reagent. Provide the professional solution that is very friendly in terms of resource utilization. 

 

Endotoxin free microplates MPMC96: the strip is individual wrap, 8 wells a strips, provide economical solution for the micro kinetic chromogenic assay.
Kinetic microplate reader Elx808 or others Elx808 series.

Pyrogen free microplate

 


Product detail pictures:

Factory Cheap Hot Chromogenic LAL test - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo detail pictures

Factory Cheap Hot Chromogenic LAL test - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo detail pictures

Factory Cheap Hot Chromogenic LAL test - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo detail pictures

Factory Cheap Hot Chromogenic LAL test - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo detail pictures


Related Product Guide:

Innovation, excellent and reliability are the core values of our firm. These principles today more than ever form the basis of our success as an internationally active mid-size corporation for Factory Cheap Hot Chromogenic LAL test - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo , The product will supply to all over the world, such as: Wellington, Iran, Juventus, Our R&D department always designs with new fashion ideas so we could introduce up-to-date fashion styles every month. Our strict production management systems always ensure stable and high quality products. Our trade team provides timely and efficient services. If there are any interest and inquiry about our products, please contact us in time. We would like to establish a business relationship with your honored company.
  • Hope that the company could stick to the enterprise spirit of "Quality, Efficiency, Innovation and Integrity", it will be better and better in the future.
    5 Stars By Dorothy from San Diego - 2018.06.28 19:27
    We have been appreciated the Chinese manufacturing, this time also did not let us disappoint,good job!
    5 Stars By Ella from Brasilia - 2017.08.16 13:39

    Leave Your Messages

    Related products

    • 2022 China New Design LAL test for endotoxin - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo

      2022 China New Design LAL test for endotoxin -...

       Endotoxin Challenge Vials (Endotoxin Indicator)   1. Product Information The Endotoxin Challenge Vial (ECV,Endotoxin Indicator) is used in the validation of dry heat depyrogenation cycles. Endotoxin Challenge Vials are placed in the cold spots of the dry heat oven. After cycle completion, the log reduction in endotoxin levels can be determined by comparing the endotoxin levels in the baked vs not baked Endotoxin Indicators. The Endotoxin Challenge vials are designed to indicate a minimum 3...

    • OEM/ODM China Dry heat sterilizer validation by ECV - Kinetic Incubating Microplate Reader ELX808IULALXH  – Bioendo

      OEM/ODM China Dry heat sterilizer validation by...

      Kinetic Incubating Microplate Reader 1. Product information Kinetic Incubating Microplate Reader Elx808 is a multifunctional kinetic reader designed for bacterial endotoxin assay, fungi (1,3)-ß-D-glucan assay and ELISA assays. The reader is a highly accurate, easy to use instrument for kinetic turbidimetric LAL/TAL assay, kinetic chromogenic LAL test and endpoint chromogenic LAL assay.  Compare to kinetic incubating tube reader,the microplate reader is more efficient and is possible to be sc...

    • Wholesale Kinetic Turbidimetric TAL Test - Kinetic Turbidimetric Amebocyte Lysate Vial – Bioendo

      Wholesale Kinetic Turbidimetric TAL Test - Kin...

      Kinetic Turbidimetric Amebocyte Lysate Vial 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration.  2. Product Parame...

    • Factory wholesale Depyrogenated microplate - Compact Modular Dry Heat Incubator – Bioendo

      Factory wholesale Depyrogenated microplate - C...

      Dry Heat Incubator 1. Product description: Dry Heat Incubator TAL-M2 is amicroprocessor-controlled device, high precision of temperature control, samplepreparation parallelism, as an alternative to the traditional water bathdevice. It is recommended to use in the gel clot TAL endotoxin assay. And it can be widely used in various other application includes the pharmaceutical, chemical, food safety, environment, quality inspection. TAL-M2 includes 2 heating modules. TAL- M2 A Dry bath incubat...

    • Wholesale Price China Kinetic Turbidimetric LAL kit for endotoxin detection - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo

      Wholesale Price China Kinetic Turbidimetric LAL...

      Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration. T...

    • Manufactur standard Endotossine LAL Test - Endotoxin Assay and (1,3)-ß-D-glucan assay software – Bioendo

      Manufactur standard Endotossine LAL Test - End...

      Endotoxin and (1,3)-ß-D-glucan assay software 1. Product information Endotoxin and (1,3)-ß-D-glucan assay software is a powerful kinetic data analysis software,which gives the user data acquisition and processing of the maximum flexibility. Features: • Apply to Endotoxin assay,(1,3)-ß-D-glucan assay and ELISA data analysis • With standard version and clinical diagnostic version for the different user groups. • Data could be output transitions and connected to the LIS system. • Customizabl...