Our business puts emphasis over the administration, the introduction of talented staff, plus the construction of team building, attempting hard to boost the standard and liability consciousness of personnel customers. Our corporation successfully attained IS9001 Certification and European CE Certification of Pyrogen free microplate, LAL chromogenic test, Bacterial Endotoxins Test, We are sincerely looking forward to cooperate with customers all over the world. We believe we can satisfy with you. We also warmly welcome customers to visit our factory and purchase our products.
Factory Supply LAL Turbidimetric assay - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo Detail:

Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay)

1. Product Introduction

Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration.
The kit contains Lyophilized Amebocyte Lysate, Control Standard Endotoxin, and Water for BET. KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) require a kinetic microplate reader such as ELx808IULALXH or a kinetic tube reader. Kinetic software is also required for calculation of the endotoxin concentration.

2. Product Parameter

Assay Range: 0.005 – 5EU/ml; 0.01 – 10EU/ml

3. Product Application

End-product endotoxin (pyrogen) qualification, Waterfor injection endotoxin assay, raw material endotoxin testing or endotoxinlevel monitoring during manufacturing process for pharmaceutical companies ormedical devices manufacturers.

Note:

Lyophilized Amebocyte Lysate reagent manufactured by Bioendo is made from amebocyte lysate from the horseshoe crab (Tachypleus tridentatus).

Catalog No.

Description

Kit Contents

Sensitivity EU/ml

KT0817

Bioendo™ KT Endotoxin Test Kit

(Kinetic Turbidimetric Assay), 128 tests/kit

8 Lyophilized Amebocyte Lysate, 1.7ml (16 Tests/vial);

8 Reconstitution Buffer, 3.0ml/vial;

4 CSE; 2 Water for BET, 50ml/vial;

0.01-10EU/ml

KT0817S

0.005-5EU/ml,

0.01-10EU/ml

KT0852

Bioendo™ KT Endotoxin Test Kit

(Kinetic Turbidimetric Assay), 400 Tests/Kit

8 Lyophilized Amebocyte Lysate, 5.2ml (50 Tests/Vial);

8 Reconstitution Buffer, 6.0ml/vial;

4 CSE; 3 Water for BET, 50ml/vial;

0.01-10EU/ml

KT0852S

0.005-5EU/ml,

0.01-10EU/ml

KT5017

Bioendo™ KT Endotoxin Test Kit

(Kinetic Turbidimetric Assay), 800 Tests/Kit

50 Lyophilized Amebocyte Lysate, 1.7ml (16 Tests/vial);

50 Reconstitution Buffer, 3.0ml/vial; 10 CSE;

0.01-10EU/ml

KT5017S

0.005-5EU/ml,

0.01-10EU/ml

KT5052

Bioendo™ KT Endotoxin Test Kit

(Kinetic Turbidimetric Assay), 2500 Tests/Kit

50 Lyophilized Amebocyte Lysate,5.2ml (50 Tests/vial);

50 Reconstitution Buffer, 6.0ml/vial; 10 CSE;

0.01-10EU/ml

KT5052S

0.005-5EU/ml,

0.01-10EU/ml

Product Condition:

The potency of Lyophilized Amebocyte Lysate and Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis, MSDS.


Product detail pictures:

Factory Supply LAL Turbidimetric assay - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo detail pictures

Factory Supply LAL Turbidimetric assay - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo detail pictures

Factory Supply LAL Turbidimetric assay - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo detail pictures

Factory Supply LAL Turbidimetric assay - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo detail pictures

Factory Supply LAL Turbidimetric assay - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo detail pictures


Related Product Guide:

We not only will try our greatest to supply outstanding services to every shopper, but also are ready to receive any suggestion offered by our buyers for Factory Supply LAL Turbidimetric assay - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo , The product will supply to all over the world, such as: Sydney, Suriname, Armenia, Our Company has qualified engineers and technical staff to answer your questions about maintenance problems, some common failure. Our product quality assurance, price concessions, any questions about the items, Be sure to feel free to contact us.
  • Sales manager is very enthusiastic and professional, gave us a great concessions and product quality is very good,thank you very much!
    5 Stars By Deirdre from Australia - 2018.10.01 14:14
    This company has the idea of "better quality, lower processing costs, prices are more reasonable", so they have competitive product quality and price, that's the main reason we chose to cooperate.
    5 Stars By Rebecca from Manchester - 2018.02.12 14:52

    Leave Your Messages

    Related products

    • OEM/ODM China Dry heat sterilizer validation by ECV - Rapid Gel Clot 10 Samples Kit – Bioendo

      OEM/ODM China Dry heat sterilizer validation by...

      Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit) 1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedure...

    • OEM Customized Endotixins - Rapid Gel Clot single test kit – Bioendo

      OEM Customized Endotixins - Rapid Gel Clot sin...

      Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit) 1. Product Information Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures ...

    • OEM China Endotoxin Detection Kit - Control Standard Endotoxin (CSE) – Bioendo

      OEM China Endotoxin Detection Kit - Control St...

      Control Standard Endotoxin (CSE) 1. Product Information Control Standard Endotoxin (CSE) is extracted from E.coli O111:B4. CSE is an economic alternative to Reference Standard Endotoxin (RSE) in constructing standard curves, validating product and preparing controls in Lyophilized Amebocyte Lysate test. The labeled potency of CSE endotoxinE.coli standard is referenced against RSE. The Control Standard Endotoxin could be used with gel clot assay, kinetic turbidimetric assay or kinetic chromog...

    • professional factory for Endotoxin Detection Test - Control Standard Endotoxin (CSE) – Bioendo

      professional factory for Endotoxin Detection Te...

      Control Standard Endotoxin (CSE) 1. Product Information Control Standard Endotoxin (CSE) is extracted from E.coli O111:B4. CSE is an economic alternative to Reference Standard Endotoxin (RSE) in constructing standard curves, validating product and preparing controls in Lyophilized Amebocyte Lysate test. The labeled potency of CSE endotoxinE.coli standard is referenced against RSE. The Control Standard Endotoxin could be used with gel clot assay, kinetic turbidimetric assay or kinetic chromog...

    • Excellent quality Control Standard Endotoxin Dilution - Pyrogen-free (Endotoxin-free) Tris Buffer – Bioendo

      Excellent quality Control Standard Endotoxin Di...

      Pyrogen-free (Endotoxin-free) Tris Buffer 1. Product information Buffers must be validated to be free of detectable endotoxin andinterfering factors. Using 50mM Tris buffer to dissolve or dilute the testsamples is a convenient way to adjust the reaction pH. Pyrogen-free (endotoxin-free) Tris buffer to adjusting the pH of the LAL endotoxin test samples. Lyophilized Amebocyte Lysate testing microbiology detection of endotoxin by horseshoecrab blue blood lysate require certain conditions. The ...

    • Cheap PriceList for Endosafe LAL Kit - Compact Modular Dry Heat Incubator – Bioendo

      Cheap PriceList for Endosafe LAL Kit - Compact...

      Dry Heat Incubator 1. Product description: Dry Heat Incubator TAL-M2 is amicroprocessor-controlled device, high precision of temperature control, samplepreparation parallelism, as an alternative to the traditional water bathdevice. It is recommended to use in the gel clot TAL endotoxin assay. And it can be widely used in various other application includes the pharmaceutical, chemical, food safety, environment, quality inspection. TAL-M2 includes 2 heating modules. TAL- M2 A Dry bath incubat...