The pretty loaded projects management experiences and one to a person support model make the high importance of business enterprise communication and our easy understanding of your expectations for Kinetic chromogenic LAL test, Bacteria That Produce Endotoxins, Turbidimetric endotoxin assays, If you are interested in any of our products or would like to discuss a custom order, please feel free to contact us.
Factory Supply Pipette tip box - Rapid Gel Clot single test kit – Bioendo Detail:

Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit)

1. Product Information

Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes.
Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures in the operation of rapid endotoxin assay, the whole operation not required sophisticated experimental equipment, incubation by a dry heat incubator. It is especial suitable for the endotoxins analysis in the water or dialysate.

20190819091605_48802

2. Product Parameter

Sensitivity Range: 0.03EU/ml, 0.06EU/ml, 0.125EU/ml, 0.25EU/ml, 0.5EU/ml

One sample test in a kit. 

Assay time: less than 30 minutes. 

Catalog No.

Description

Kit Contents

Sensitivity

EU/ml

Reaction Time

minutes

RG025003

BioendoTM Rapid Gel Clot Endotoxin Assay Kit, One Sample Kit

1 SPL Tube;

1 PPC Tube;

1 Endotoxin-free Sample Bottle;

3 Pyrogen-free Pipettors;

0.03

≤60

RG025006

0.06

≤60

RG0250125

0.125

≤45

RG025025

0.25

≤30

RG025050

0.5

≤30

 

3. Kit Application

Bioendo single test Rapid Gel Clot Endotoxin Assay Kit provide a kind of rapid endotoxin testing solution, the featured application in the field of dialysis. 

 

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from amebocyte lysate derived blood of horseshoe crab. In the operation procedure,  the dilution of control standard endotoxin is simple and convenient. Endotoxin free sample container and pyrogen free transfer pipette is required, Sophisticated instrument is not required, recommend Bioendo Dry heat incubator TAL-MT use in the procedure of incubation. 

Kit Configuration:

Bioendo single test Rapid Gel Clot Endotoxin Assay Kit contains: 

1 piece of SPL Tube, 1 piece of PPC Tube, 1 piece of Endotoxin-free Sample Bottle. (endotoxin free top level), 

1 Pack of Transfer Pipette 3 pieces. (endotoxin free top level)


Product detail pictures:

Factory Supply Pipette tip box - Rapid Gel Clot single test kit – Bioendo detail pictures

Factory Supply Pipette tip box - Rapid Gel Clot single test kit – Bioendo detail pictures

Factory Supply Pipette tip box - Rapid Gel Clot single test kit – Bioendo detail pictures

Factory Supply Pipette tip box - Rapid Gel Clot single test kit – Bioendo detail pictures

Factory Supply Pipette tip box - Rapid Gel Clot single test kit – Bioendo detail pictures


Related Product Guide:

We insist on offering good quality generation with very good business enterprise concept, honest income as well as best and fast assistance. it will bring you not only the premium quality product or service and huge profit, but probably the most significant is usually to occupy the endless market for Factory Supply Pipette tip box - Rapid Gel Clot single test kit – Bioendo , The product will supply to all over the world, such as: Hongkong, Muscat, Milan, Profession, Devoting are always fundamental to our mission. We have always been in line with serving customers, creating value management objectives and adhering to the sincerity, dedication, persistent management idea.
  • Product variety is complete, good quality and inexpensive, the delivery is fast and transport is security, very good, we are happy to cooperate with a reputable company!
    5 Stars By Edith from Greece - 2018.08.12 12:27
    The accounts manager made a detailed introduction about the product, so that we have a comprehensive understanding of the product, and ultimately we decided to cooperate.
    5 Stars By Adam from Victoria - 2017.12.09 14:01

    Leave Your Messages

    Related products

    • Wholesale Price China LAL test for pyrogens - Rapid Gel Clot single test kit – Bioendo

      Wholesale Price China LAL test for pyrogens - ...

      Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit) 1. Product Information Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures ...

    • OEM/ODM China Dry heat sterilizer validation by ECV - Rapid Gel Clot 10 Samples Kit – Bioendo

      OEM/ODM China Dry heat sterilizer validation by...

      Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit) 1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedure...

    • Factory wholesale Endotoxin Activity Assay - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo

      Factory wholesale Endotoxin Activity Assay - B...

      Beta-glucans Blocker for Blocking Beta Glucan Pathway 1. Product information There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Gl...

    • New Arrival China Dry heat tunnel validation by ECV - Eight-channel Mechanical Pipette – Bioendo

      New Arrival China Dry heat tunnel validation by...

      Eight-Channel Mechanical Pipettor 1. Product information All multi-channel mechanical pipettor have been quality tested according to ISO8655-2:2002 with calibration certificate. The quality control involves gravimetric testing of each pipette with distilled water at 22℃. The multichannel mechanical pipettor is idea for the detectionof bacterial endotoxin lal endotoxin testing by kinetic turbidimetric andkinetic chromogenic method. - Eight-Channel Mechanical Pipettor is available for stand...

    • Top Suppliers Dry Heat Sterilizer Validation - Single-Channel Mechanical Pipettor – Bioendo

      Top Suppliers Dry Heat Sterilizer Validation -...

      Single-Channel Mechanical Pipettor   1. Product Information Single channel mechanical pipette is ideal tool to support endotoxin detection with Lyophilized Amebocyte Lysate which covers gel-clot technique, kinetic turbidimetric technique, kinetic chromogenic technique, and end-point chromogenic technique. All pipettors are produced by following ISO8655 – 2:2002. The quality control involves gravimetric testing of each pipette with distilled water at 22℃.   2. Product Features: - ...

    • PriceList for Kinetic Turbidimetric TAL Kit - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo

      PriceList for Kinetic Turbidimetric TAL Kit - ...

      Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration. T...