Free sample for Bacterial Endotoxin Test Procedure - Pyrogen-free (Endotoxin-free) Tris Buffer – Bioendo


Product Detail

Related Video

Feedback (2)

We pursue the management tenet of "Quality is remarkable, Company is supreme, Name is first", and will sincerely create and share success with all clientele for Chromogenic LAL assay, Endotoxin LAL Kit, LAL reagent sensitivity, Teamwork is encouraged at all levels with regular campaigns. Our research team experiments on various developments in the industry for improvement in the products.
Free sample for Bacterial Endotoxin Test Procedure - Pyrogen-free (Endotoxin-free) Tris Buffer – Bioendo Detail:

Pyrogen-free (Endotoxin-free) Tris Buffer

1. Product information

Buffers must be validated to be free of detectable endotoxin andinterfering factors. Using 50mM Tris buffer to dissolve or dilute the testsamples is a convenient way to adjust the reaction pH.

Pyrogen-free (endotoxin-free) Tris buffer to adjusting the pH of the LAL endotoxin test samples.

Lyophilized Amebocyte Lysate testing microbiology detection of endotoxin by horseshoecrab blue blood lysate require certain conditions. The optimal pH for theendotoxin testing Lyophilized Amebocyte Lysate reagent and endotoxin reaction is in the range of 6.0 to8.0. If the endotoxin detection test sample pH is out of this range, the pH maybe adjusted using an acid, base, or endotoxin free suitable buffers. The Acidsand bases may be prepared from concentrates or solids with Lyophilized Amebocyte Lysate Reagent Water incontainers free of detectable endotoxin.

2. Productparameter

Endotoxin level < 0.005EU/ml

3. Productfeatures and application

Adjust the pH of Lyophilized Amebocyte Lysate endotoxin testing in an easy step. Use Tris buffer to dilute the test sample, overcoming the inhibition of Lyophilized Amebocyte Lysate endotoxintesting by adjust the reaction pH to the range of pH 6.0-8.0.

Catalog No.

Description

Note

Package

BH10

50mM Tris buffer, pH7.0, 10ml/vial

Used to dilute highly acidic or basic samples.

10 vials/pack

BH50

50mM Tris buffer, pH7.0, 50ml/vial

Used to dilute highly acidic or basic samples. 

 10 vials/pack

Product Condition

The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis, MSDS.


Product detail pictures:

Free sample for Bacterial Endotoxin Test Procedure - Pyrogen-free (Endotoxin-free) Tris Buffer – Bioendo detail pictures


Related Product Guide:

Our company has been concentrating on brand strategy. Customers' pleasure is our greatest advertising. We also source OEM service for Free sample for Bacterial Endotoxin Test Procedure - Pyrogen-free (Endotoxin-free) Tris Buffer – Bioendo , The product will supply to all over the world, such as: Karachi, New Zealand, belarus, All our products are exported to clients in the UK, Germany, France, Spain, the USA, Canada, Iran, Iraq, the Middle East and Africa. Our products are well welcomed by our customers for the high quality, competitive prices and the most favorable styles. We hope to establish business relationship with all customers and bring more beautifu colors for the life.
  • The company's products very well, we have purchased and cooperated many times, fair price and assured quality, in short, this is a trustworthy company!
    5 Stars By Tyler Larson from Hungary - 2018.12.22 12:52
    The goods are very perfect and the company sales manager is warmful, we will come to this company to purchase next time.
    5 Stars By Andrea from Denver - 2018.10.09 19:07

    Leave Your Messages

    Related products

    • Good quality Micro kinetic chromogenic endotoxin test kit - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo

      Good quality Micro kinetic chromogenic endotoxi...

      Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) 1. Product Information In Bioendo KC Endotoxin Test Kit, Amebocyte Lysate is co-lyophilized with chromogenic substrate. Therefore, bacterial endotoxin could be quantified based on the chromogenic reaction. The assay is strong resistance to interference, and has advantages of kinetic turbidimetric and end-point chromogenic method. Bioendo Endotoxin Test Kit contains Chromogenic Amebocyte Lysate, Reconstitution Buffer, CSE, Water for BE...

    • 2022 China New Design Kinetic Turbidimetric Assay - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo

      2022 China New Design Kinetic Turbidimetric Ass...

      Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration. T...

    • Fast delivery Endotoxin Free tip - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo

      Fast delivery Endotoxin Free tip - Pyrogen-fre...

      Pyrogen-free Microplates, 96 Well Plate Strips and pyrogen free Reagent Reservoir 1. Product information These pyrogen-free 96-well plates (endotoxin-free microplates, pyrogen-free reservoir, cell culture plate, endotoxin-free plates) is used in the End-point Chromogenic Lyophilized Amebocyte Lysate Assay, Kinetic Chromogenic Lyophilized Amebocyte Lysate Assay and Kinetic Turbidimetric  endotoxin test assay. The microplates and resevoirs contain endotoxins <0.005 EU/ml endotoxin. Catalog...

    • OEM manufacturer Endotoxin Elisa Kit - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo

      OEM manufacturer Endotoxin Elisa Kit - Beta-gl...

      Beta-glucans Blocker for Blocking Beta Glucan Pathway 1. Product information There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Gl...

    • Chinese Professional LAL testing medical devices - Endotoxin Assay Kit for Human Plasma – Bioendo

      Chinese Professional LAL testing medical device...

      Endotoxin Assay Kit for Human Plasma 1. Product Information CFDA cleared Clinical diagnostic Endotoxin assay kit quantifies endotoxin level inhuman plasma. Endotoxin is a major component of the cell wall of Gram Negative bacteria and is the most important microbial mediator of sepsis. Elevated levels of endotoxin can often induce fever, changes in white blood cell countsand, in some cases, cardiovascular shock. It is based on the factor Cpathway in limulus Polyphemus (horseshoe crab blood) t...

    • Factory Supply Kinetic chromogenic LAL Assay kit - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo

      Factory Supply Kinetic chromogenic LAL Assay ki...

       Micro KC Endotoxin Test Kit (Micro Kinetic Chromogenic Endotoxin Assay) The Bioendo MicroKC Endotoxin Test Kit (Micro Kinetic Chromogenic Endotoxin Assay), which adopts the micro-technical kinetic chromogenic method, is equipped with a special customized 96-well microplates, which can be used in the endotoxin test of microbial detection system Elx808IULALXH and other conventional endotoxin detection equipment to realize the micro-kinetic chromogenic endotoxin detection. The micro KC kit mee...