No matter new customer or outdated client, We believe in extensive phrase and trusted relationship for Kinetic Turbidimetric Method of endotoxin testing, LAL Turbidimetric detection, Bacterial Endotoxin Test For Water For Injection, We are going to empower people by communicating and listening, Setting an example to others and learning from experience.
Good quality Chromogenic Endotoxin Quant Kit - Endpoint Chromogenic Kit EC64405 – Bioendo Detail:

End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling)

1. Product Information

End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is conducted by adding a colorless artificial peptide substrate solution into mixture of Lyophilized Amebocyte Lysate and test sample after a certain incubation period. If test sample contain endotoxin, a yellow color will develop in the 96 well microplate. Its absorbance (λmax = 405nm) is related to the endotoxin concentration. Endotoxin concentration of test sample could be calculated based on a standard curve.

2. Product parameter

Sensitivity Range: 0.01-0.1 EU/ml, matching assay time is about 46 minutes

                              0.1-1 EU/ml, matching assay time is about 16 minutes. 

3. Product Features and Application

End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is intended for use in the In Vitro detection and quantitation of gram-negative bacterial endotoxins. The colorless artificial peptide substrate solution is added into the mixture of Lyophilized Amebocyte Lysate and test sample after a certain incubation period. Yellow color develops if test sample contains endotoxin. Then use regular spectrophotometer or plate reader to read the absorbance at 405nm. End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is suitable for all kinds of biomedical samples such as protein, vaccine, plasmid, DNA, RNA endotoxin assay. 

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from amebocyte lysate derived blood of horseshoe crab.

Catalog No.

Description

Kit Contents

Sensitivity

(EU/ml)

EC64405

 

Bioendo™ EC Endotoxin Test Kit (End-point Chromogenic Assay),

64 Tests/Kit

 

2 Lyophilized Amebocyte Lysate, 1.7ml/vial;

2 Water for BET, 50ml/vial;  

2 CSE;

4 Chromogenic Substrate, 1.7ml/vial;

0.1 – 1 EU/ml

EC64405S

0.01 – 0.1 EU/ml;

0.1 – 1 EU/m

Product Condition:

The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis.

 

Does the End point endotoxin test kit need sophisticated microplate reader?

Bioendo EC64405 and EC64405S kit analysis the quantitative endotoxin results through regular microplate reader. 

End point chromogenic endotoxin test kit series:

Endotoxin Free Tube

Pyrogen Free Tips

Pyrogen Free Microplates

Regular Microplate reader

Matched Control standard endotoxin (CSE10V)

BET water use for reconstitution. 

 



Product detail pictures:

Good quality Chromogenic Endotoxin Quant Kit - Endpoint Chromogenic Kit EC64405 – Bioendo detail pictures

Good quality Chromogenic Endotoxin Quant Kit - Endpoint Chromogenic Kit EC64405 – Bioendo detail pictures

Good quality Chromogenic Endotoxin Quant Kit - Endpoint Chromogenic Kit EC64405 – Bioendo detail pictures

Good quality Chromogenic Endotoxin Quant Kit - Endpoint Chromogenic Kit EC64405 – Bioendo detail pictures


Related Product Guide:

Having a positive and progressive attitude to customer's fascination, our organization constantly improves our solution high-quality to fulfill the requirements of shoppers and further focuses on safety, reliability, environmental prerequisites, and innovation of Good quality Chromogenic Endotoxin Quant Kit - Endpoint Chromogenic Kit EC64405 – Bioendo , The product will supply to all over the world, such as: Toronto, Miami, Oman, Profession, Devoting are always fundamental to our mission. We've got always been in line with serving customers, creating value management objectives and adhering to the sincerity, dedication, persistent management idea.
  • The company's products can meet our diverse needs, and the price is cheap, the most important is that the quality is also very nice.
    5 Stars By Matthew Tobias from Yemen - 2018.09.16 11:31
    The factory has advanced equipment, experienced staffs and good management level, so product quality had assurance, this cooperation is very relaxed and happy!
    5 Stars By Cindy from Tunisia - 2017.03.28 16:34

    Leave Your Messages

    Related products

    • Factory wholesale Amebocyte Lysate - Endotoxin-specific Lyophilized Amebocyte Lysate – Bioendo

      Factory wholesale Amebocyte Lysate - Endotoxin...

      Endotoxin-specific Lyophilized Amebocyte Lysate 1. Product Information Lyophilized Amebocyte Lysate extracted from horseshoe crab contains factor C pathway which reacts to endotoxin and factor G pathway which reacts to (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate contains ß-Glucan inhibitor, which will avoid false positive, result happening between factor C pathway and (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate is especially suitable for samples ...

    • Factory Cheap Hot Kinetic Turbidimetric Endotoxin test Kit - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo

      Factory Cheap Hot Kinetic Turbidimetric Endotox...

      Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration. T...

    • Free sample for Bacterial Endotoxin Test Procedure - Pyrogen-free (Endotoxin-free) Tris Buffer – Bioendo

      Free sample for Bacterial Endotoxin Test Proced...

      Pyrogen-free (Endotoxin-free) Tris Buffer 1. Product information Buffers must be validated to be free of detectable endotoxin andinterfering factors. Using 50mM Tris buffer to dissolve or dilute the testsamples is a convenient way to adjust the reaction pH. Pyrogen-free (endotoxin-free) Tris buffer to adjusting the pH of the LAL endotoxin test samples. Lyophilized Amebocyte Lysate testing microbiology detection of endotoxin by horseshoecrab blue blood lysate require certain conditions. The ...

    • Manufactur standard Endotoxin Lps - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo

      Manufactur standard Endotoxin Lps - Endotoxin ...

       Endotoxin Challenge Vials (Endotoxin Indicator)   1. Product Information The Endotoxin Challenge Vial (ECV,Endotoxin Indicator) is used in the validation of dry heat depyrogenation cycles. Endotoxin Challenge Vials are placed in the cold spots of the dry heat oven. After cycle completion, the log reduction in endotoxin levels can be determined by comparing the endotoxin levels in the baked vs not baked Endotoxin Indicators. The Endotoxin Challenge vials are designed to indicate a minimum 3...

    • 2022 Latest Design Bioburden And Endotoxin Testing - Pyrogen-free (Endotoxin-free) Tris Buffer – Bioendo

      2022 Latest Design Bioburden And Endotoxin Test...

      Pyrogen-free (Endotoxin-free) Tris Buffer 1. Product information Buffers must be validated to be free of detectable endotoxin andinterfering factors. Using 50mM Tris buffer to dissolve or dilute the testsamples is a convenient way to adjust the reaction pH. Pyrogen-free (endotoxin-free) Tris buffer to adjusting the pH of the LAL endotoxin test samples. Lyophilized Amebocyte Lysate testing microbiology detection of endotoxin by horseshoecrab blue blood lysate require certain conditions. The ...

    • OEM Manufacturer BET Test Procedure - Pyrogen-free Centrifuge Tube – Bioendo

      OEM Manufacturer BET Test Procedure - Pyrogen-...

      Pyrogen-free Centrifuge Tube   Product features: * Pyrogen-free Centrifuge tube is made from virgin polypropylene to meet the general requirements of the laboratory. * Pyrogen-free, Endotoxin level <0.005EU/ml * High strength non-toxic materials * Printed clear graduations with marking area * Gamma Radiation Sterilized * 50ml Maximum RCF is 18000g, 15ml Maximum RCF is 12000g * DNase/RNase free * Autoclavable * Temperature range is -20°C to 121°C * Leak-proof * Cap 50% longer ideal for avo...