Hot sale Endpoint Chromogenic Endotoxin test kit - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo


Product Detail

Related Video

Feedback (2)

Our advantages are lower prices,dynamic sales team,specialized QC,strong factories,high quality products and services for Bacterial Endotoxin Test Gel Clot Method Sop, Dry heat tunnel validation by ECV, Endotoxin LAL Assay, We sincerely welcome overseas customers to consult for the long-term cooperation and the mutual development.We strongly believe that we can do better and better.
Hot sale Endpoint Chromogenic Endotoxin test kit - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo Detail:

Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay)

1. Product Information

In Bioendo KC Endotoxin Test Kit, Amebocyte Lysate is co-lyophilized with chromogenic substrate. Therefore, bacterial endotoxin could be quantified based on the chromogenic reaction. The assay is strong resistance to interference, and has advantages of kinetic turbidimetric and end-point chromogenic method. Bioendo Endotoxin Test Kit contains Chromogenic Amebocyte Lysate, Reconstitution Buffer, CSE, Water for BET. Endotoxin detection with Kinetic Chromogenic method requires a kinetic incubating microplate reader such as ELx808IULALXH.

 

2. Product Parameter

Assay Range: 0.005 – 50EU/ml; 0.001 – 10EU/ml

Catalog No.

Description

Kit Contents

Sensitivity EU/ml

KC5028

Bioendo™ KC Endotoxin Test Kit (Kinetic Chromogenic Assay),

1300 Tests/Kit

50 Chromogenic Amebocyte Lysate,

2.8ml (26 Tests/Vial);

50 Reconstitution Buffer, 3.0ml/vial; 

10CSE; 

0.005-5EU/ml

KC5028S

0.001-10EU/ml

KC0828

Bioendo™ KC Endotoxin Test Kit (Kinetic Chromogenic Assay),

 208 Tests/Kit

8 Chromogenic Amebocyte Lysate,

2.8ml (26 Tests/Vial);

8 Reconstitution Buffer, 3.0ml/vial;

4 CSE; 

2 Water for BET, 50ml/vial;

0.005-5EU/ml

KC0828S

0.001-10EU/ml

KC5017

Bioendo™ KC Endotoxin Test Kit (Kinetic Chromogenic Assay),

800 Tests/Kit

50 Chromogenic Amebocyte Lysate,

1.7ml (16 Tests/Vial);

50 Reconstitution Buffer, 2.0ml/vial; 

10CSE; 

0.005-5 EU/ml

KC5017S

0.001-10 EU/m

KC0817

Bioendo™ KC Endotoxin Test Kit (Kinetic Chromogenic Assay),

128 Tests/kit

8 Kinetic Chromogenic Amebocyte Lysate, 

1.7ml (16 Tests/vial);

8 Reconstitution Buffer, 2.0ml/vial;

4 CSE;

2 Water for BET, 50ml/vial;

0.005-5 EU/ml

KC0817S

0.001-10 EU/ml

 

3. Product Feature and Application

BioendoTM KC Endotoxin Test Kit (Kinetic Chromogenic Assay) features strong resistance to interference, and has advantages of kinetic turbidimetric and end-point chromogenic method. It is especially suitable for endotoxin detection of biological samples like vaccine, antibody, protein, nucleic acid, etc.

Note:

Lyophilized Amebocyte Lysate reagent manufactured by Bioendo is made from amebocyte lysate from the horseshoe crab (Tachypleus tridentatus).

Product Condition:

The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis. 

The kinetic chromogenic endotoxin test kit have to choose the microplate reader with 405nm filters.


Product detail pictures:

Hot sale Endpoint Chromogenic Endotoxin test kit - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo detail pictures

Hot sale Endpoint Chromogenic Endotoxin test kit - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo detail pictures

Hot sale Endpoint Chromogenic Endotoxin test kit - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo detail pictures

Hot sale Endpoint Chromogenic Endotoxin test kit - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo detail pictures

Hot sale Endpoint Chromogenic Endotoxin test kit - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo detail pictures


Related Product Guide:

To get the stage of realizing dreams of our employees! To build a happier, more united and much more skilled crew! To reach a mutual benefit of our prospects, suppliers, the society and ourselves for Hot sale Endpoint Chromogenic Endotoxin test kit - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo , The product will supply to all over the world, such as: Nicaragua, Sacramento, Slovenia, We have more than 200 staff including experienced managers, creative designers, sophisticated engineers and skilled workers. Through hard work of all employees for the past 20 years own company grew stronger and stronger. We always apply the "client first" principle. We also always fulfill all contracts to the point and therefore enjoy excellent reputation and trust among our customers. You are very welcome to personally visit our company.We hope to start a business partnership on the basis of mutual benefit and successful development . For more information please do no hesitate to contact us..
  • The company keeps to the operation concept "scientific management, high quality and efficiency primacy, customer supreme", we have always maintained business cooperation. Work with you,we feel easy!
    5 Stars By Elsa from Argentina - 2018.11.22 12:28
    Good quality, reasonable prices, rich variety and perfect after-sales service, it's nice!
    5 Stars By Annabelle from Brisbane - 2018.07.12 12:19

    Leave Your Messages

    Related products

    • Popular Design for Endotoxin Indicator For Depyrogenation - Endotoxin-free Glass Test Tubes – Bioendo

      Popular Design for Endotoxin Indicator For Depy...

      Endotoxin-free Glass Test Tubes   1. Product Information Endotoxin-free glass test tubes contain less than 0.005EU/ml endotoxin. Catalog number T107505 and T107540  are recommended for use as reaction tubes in gel clot and end-point chromogenic assays. Catalog number T1310018 and T1310005 is recommended for dilution of endotoxin standards and test samples. T1050005C is a special designed short endotoxin reaction tube that allows the pipette tips reaches the tube bottom. T087565 is used ...

    • Excellent quality Depyrogenated pipette tips - Rapid Gel Clot 10 Samples Kit – Bioendo

      Excellent quality Depyrogenated pipette tips -...

      Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit) 1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedure...

    • Hot sale Endotoxin Indicator Vials Manufacturer - Endotoxin-free Glass Test Tubes – Bioendo

      Hot sale Endotoxin Indicator Vials Manufacturer...

      Endotoxin-free Glass Test Tubes   1. Product Information Endotoxin-free glass test tubes contain less than 0.005EU/ml endotoxin. Catalog number T107505 and T107540  are recommended for use as reaction tubes in gel clot and end-point chromogenic assays. Catalog number T1310018 and T1310005 is recommended for dilution of endotoxin standards and test samples. T1050005C is a special designed short endotoxin reaction tube that allows the pipette tips reaches the tube bottom. T087565 is used ...

    • China OEM Data Logger For Oven Validation - Nymph X Water Purification System – Bioendo

      China OEM Data Logger For Oven Validation - Ny...

      NYMPHX Nymph X Water Purification System   Nymph X Water Purification System could transfer tap water into pure water and ultrapure water. Equipped with a pressure stabilizer and low flow-rate operating mode, the system can adapt to various source conditions without any extra pre-treatment necessary. The system also supports multiple water dispensing modes, and the precision of quantitative and quality-controlled dispense of water could reach ±1%. Meanwhile, comprehensive monitoring could be...

    • OEM/ODM China Bacterial Endotoxin Test Gel Clot Method Sop - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo

      OEM/ODM China Bacterial Endotoxin Test Gel Clot...

      Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule 1. Product Information Gel Clot Lyophilized Amebocyte Lysate Single Test in ampoule Contain endotoxin-specific Amebocyte Lysate which includes beta-glucan inhibitor in the formulation and will not react to beta-glucan. For our Single Test in glass ampoule, you could add sample to the glass ampoules directly. This means you don’t need to reconstitute Amebocyte Lysate at first, and you will decide how many tests use each time to avoi...

    • Factory source Endotoxin LAL Assay - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo

      Factory source Endotoxin LAL Assay - Endotoxin...

       Endotoxin Challenge Vials (Endotoxin Indicator)   1. Product Information The Endotoxin Challenge Vial (ECV,Endotoxin Indicator) is used in the validation of dry heat depyrogenation cycles. Endotoxin Challenge Vials are placed in the cold spots of the dry heat oven. After cycle completion, the log reduction in endotoxin levels can be determined by comparing the endotoxin levels in the baked vs not baked Endotoxin Indicators. The Endotoxin Challenge vials are designed to indicate a minimum 3...