Manufacturer for LAL endotoxin kit - Pyrogen-free (Endotoxin-free) Tris Buffer – Bioendo


Product Detail

Related Video

Feedback (2)

We have now a hugely efficient team to deal with inquiries from buyers. Our goal is "100% client gratification by our solution high-quality, rate & our team service" and take pleasure in a great popularity among clients. With several factories, we will provide a wide assortment of Bacterial Endotoxin Limit For Injection, Turbidimetric LAL assay, Turbidimetric endotoxin assays, We have now a experienced crew for international trade. We are able to solve the problem you meet. We are able to offer the products and solutions you want. You should really feel free of charge to speak to us.
Manufacturer for LAL endotoxin kit - Pyrogen-free (Endotoxin-free) Tris Buffer – Bioendo Detail:

Pyrogen-free (Endotoxin-free) Tris Buffer

1. Product information

Buffers must be validated to be free of detectable endotoxin andinterfering factors. Using 50mM Tris buffer to dissolve or dilute the testsamples is a convenient way to adjust the reaction pH.

Pyrogen-free (endotoxin-free) Tris buffer to adjusting the pH of the LAL endotoxin test samples.

Lyophilized Amebocyte Lysate testing microbiology detection of endotoxin by horseshoecrab blue blood lysate require certain conditions. The optimal pH for theendotoxin testing Lyophilized Amebocyte Lysate reagent and endotoxin reaction is in the range of 6.0 to8.0. If the endotoxin detection test sample pH is out of this range, the pH maybe adjusted using an acid, base, or endotoxin free suitable buffers. The Acidsand bases may be prepared from concentrates or solids with Lyophilized Amebocyte Lysate Reagent Water incontainers free of detectable endotoxin.

2. Productparameter

Endotoxin level < 0.005EU/ml

3. Productfeatures and application

Adjust the pH of Lyophilized Amebocyte Lysate endotoxin testing in an easy step. Use Tris buffer to dilute the test sample, overcoming the inhibition of Lyophilized Amebocyte Lysate endotoxintesting by adjust the reaction pH to the range of pH 6.0-8.0.

Catalog No.

Description

Note

Package

BH10

50mM Tris buffer, pH7.0, 10ml/vial

Used to dilute highly acidic or basic samples.

10 vials/pack

BH50

50mM Tris buffer, pH7.0, 50ml/vial

Used to dilute highly acidic or basic samples. 

 10 vials/pack

Product Condition

The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis, MSDS.


Product detail pictures:

Manufacturer for LAL endotoxin kit - Pyrogen-free (Endotoxin-free) Tris Buffer – Bioendo detail pictures


Related Product Guide:

The very rich projects management experiences and one to one service model make the high importance of business communication and our easy understanding of your expectations for Manufacturer for LAL endotoxin kit - Pyrogen-free (Endotoxin-free) Tris Buffer – Bioendo , The product will supply to all over the world, such as: Uruguay, Tanzania, Czech Republic, "Make the women more attractive "is our sales philosophy. "Being customers' trusted and preferred brand supplier" is the goal of our company. We are strict with every part of our work. We sincerely welcome friends to negotiate business and start cooperation. We hope to join hands with friends in different industries to create a brilliant future.
  • It can be said that this is a best producer we encountered in China in this industry, we feel lucky to work with so excellent manufacturer.
    5 Stars By Hilary from Rio de Janeiro - 2017.11.20 15:58
    Customer service staff and sales man are very patience and they all good at English, product's arrival is also very timely, a good supplier.
    5 Stars By Griselda from Canada - 2018.12.25 12:43

    Leave Your Messages

    Related products

    • 2022 Latest Design Bioburden And Endotoxin Testing - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo

      2022 Latest Design Bioburden And Endotoxin Test...

       Endotoxin Challenge Vials (Endotoxin Indicator)   1. Product Information The Endotoxin Challenge Vial (ECV,Endotoxin Indicator) is used in the validation of dry heat depyrogenation cycles. Endotoxin Challenge Vials are placed in the cold spots of the dry heat oven. After cycle completion, the log reduction in endotoxin levels can be determined by comparing the endotoxin levels in the baked vs not baked Endotoxin Indicators. The Endotoxin Challenge vials are designed to indicate a minimum 3...

    • PriceList for LAL chromogenic assay - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo

      PriceList for LAL chromogenic assay - Bioendo ...

      Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) 1. Product Information In Bioendo KC Endotoxin Test Kit, Amebocyte Lysate is co-lyophilized with chromogenic substrate. Therefore, bacterial endotoxin could be quantified based on the chromogenic reaction. The assay is strong resistance to interference, and has advantages of kinetic turbidimetric and end-point chromogenic method. Bioendo Endotoxin Test Kit contains Chromogenic Amebocyte Lysate, Reconstitution Buffer, CSE, Water for BE...

    • OEM Factory for BET Test Principle - Mini Dry Heat Incubator – Bioendo

      OEM Factory for BET Test Principle - Mini Dry ...

      Dry heat incubator single module 1. Product information  The Mini Dry Heat Incubator is a micro-processor controlled heating block with semi conductor heating technology.It adapts onboard use, smart, light and convenient for movement, suit for any kind of occasions. Especially good for the incubation of the gel clot LAL assay, LAL chromogenic endpoint assay incubation. 2. Product features 1. Unique designed. Smart and light, convenient movement, suit for various occasions. 2. LCD simultaneou...

    • Chinese Professional LAL test kit price - Rapid Gel Clot single test kit – Bioendo

      Chinese Professional LAL test kit price - Rapi...

      Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit) 1. Product Information Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures ...

    • Hot New Products LAL reagent sensitivity - Rapid Gel Clot 10 Samples Kit – Bioendo

      Hot New Products LAL reagent sensitivity - Rap...

      Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit) 1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedure...

    • Manufacturing Companies for Bacteria Endotoxin Test - Endotoxin-free Glass Test Tubes – Bioendo

      Manufacturing Companies for Bacteria Endotoxin ...

      Endotoxin-free Glass Test Tubes   1. Product Information Endotoxin-free glass test tubes contain less than 0.005EU/ml endotoxin. Catalog number T107505 and T107540  are recommended for use as reaction tubes in gel clot and end-point chromogenic assays. Catalog number T1310018 and T1310005 is recommended for dilution of endotoxin standards and test samples. T1050005C is a special designed short endotoxin reaction tube that allows the pipette tips reaches the tube bottom. T087565 is used ...