Manufacturer for Rapid Gel Clot Test Kit - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo


Product Detail

Related Video

Feedback (2)

To regularly increase the management program by virtue from the rule of "sincerely, good religion and high quality are the base of enterprise development", we greatly absorb the essence of linked products internationally, and constantly produce new goods to satisfy the calls for of shoppers for Bacterial Endotoxins Test Usp, Chromogenic LAL assay, Endotoxin Cleaning, We guaranteed quality, if customers were not satisfied with the products' quality, you can return within 7days with their original states.
Manufacturer for Rapid Gel Clot Test Kit - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo Detail:

Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule

1. Product Information

Gel Clot Lyophilized Amebocyte Lysate Single Test in ampoule Contain endotoxin-specific Amebocyte Lysate which includes beta-glucan inhibitor in the formulation and will not react to beta-glucan. For our Single Test in glass ampoule, you could add sample to the glass ampoules directly. This means you don’t need to reconstitute Amebocyte Lysate at first, and you will decide how many tests use each time to avoid waste. Endotoxin free tubes for the dilution of Lyophilized CSE is necessary. Operation of endotoxin detection use Bioendo Gel Clot Lyophilized Amebocyte Lysate Single Test in ampoule conforms to the national Pharmacopoeia.  

2. Product Parameter

Gel clot assay single test glass ampoule.

Sensitivities:  0.03EU/ml, 0.06EU/ml, 0.125EU/ml, 0.25 EU/ml, 0.5EU/ml. 

3.Product Feature and Application

Single step endotoxin detection,

Normal water bath or dry heat incubator is available for the gel clot method. 

Suitable for end-product endotoxin testing before product released.

Product sensitivity standardized according to the China Pharmacopoeia criterion.

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from lysate of amebocytes (white blood cells) from the horseshoe crab.

Catalog No.

Sensitivity EU/ml

Description

Kit Contents

GS010030

0.03

Bioendo Gel Clot Endotoxin Test Kit, Single Test in Ampoule.

10 tests per pack

GS010060

0.06

GS010125

0.125

GS010250

0.25

GS010500

0.5

Product Condition

The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis.

Why the most selected gel clot assay kit G01:

1. The most economical and commonly used test reagent for endotoxin detection.

2. Single test in a ampoule for one step reduce the risk of contamination.

3. Gel clot assay single test glass ampoule no need sophisticated microplate reader.

4. Saving endotoxin free tube when using G01 series to test endotoxins in the procedure of endotoxin test assay’s operation.

Related products in the endotoxin test assay:
Water for Bacterial Endotoxins Test (BET),  Recommend TRW02, TRW50 or TRW100
Endotoxin free glass tube ( dilution tube ),  Recommend T1310018
Pyrogen free tips,  Recommend PT25096 or PT100096
Pipettor, Recommend PSB0220
Test Tube Rack,
Incubation Instrument (Water Bath or Dry Heat Incubator ), Recommend Dry Heat Incubator TAL-M2
Vortex Mixter, Recommend VXH.
Control Standard Endotoxin, CSE10A.

Product detail pictures:

Manufacturer for Rapid Gel Clot Test Kit - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo detail pictures

Manufacturer for Rapid Gel Clot Test Kit - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo detail pictures

Manufacturer for Rapid Gel Clot Test Kit - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo detail pictures


Related Product Guide:

Assume full accountability to satisfy all demands of our consumers; reach ongoing advancements by endorsing the expansion of our purchasers; come to be the final permanent cooperative partner of clients and maximize the interests of clientele for Manufacturer for Rapid Gel Clot Test Kit - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo , The product will supply to all over the world, such as: Curacao, Albania, Myanmar, During in 11 years, We have participated in more than 20 exhibitions, obtains the highest praise from each customer. Our company has been devoting that "customer first" and committed to helping customers expand their business, so that they become the Big Boss !
  • Reasonable price, good attitude of consultation, finally we achieve a win-win situation,a happy cooperation!
    5 Stars By Beulah from Provence - 2018.02.12 14:52
    This is a very professional and honest Chinese supplier, from now on we fell in love with the Chinese manufacturing.
    5 Stars By Odelia from Croatia - 2017.12.02 14:11

    Leave Your Messages

    Related products

    • OEM/ODM China Dry heat sterilizer validation by ECV - Pyrogen-free Centrifuge Tube – Bioendo

      OEM/ODM China Dry heat sterilizer validation by...

      Pyrogen-free Centrifuge Tube   Product features: * Pyrogen-free Centrifuge tube is made from virgin polypropylene to meet the general requirements of the laboratory. * Pyrogen-free, Endotoxin level <0.005EU/ml * High strength non-toxic materials * Printed clear graduations with marking area * Gamma Radiation Sterilized * 50ml Maximum RCF is 18000g, 15ml Maximum RCF is 12000g * DNase/RNase free * Autoclavable * Temperature range is -20°C to 121°C * Leak-proof * Cap 50% longer ideal for avo...

    • Reasonable price Chromogenic LAL Endotoxin Assay Kit - Endpoint Chromogenic Kit EC64405 – Bioendo

      Reasonable price Chromogenic LAL Endotoxin Assa...

      End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) 1. Product Information End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is conducted by adding a colorless artificial peptide substrate solution into mixture of Lyophilized Amebocyte Lysate and test sample after a certain incubation period. If test sample contain endotoxin, a yellow color will develop in the 96 well microplate. Its absorbance (λmax = 405nm) is related to the endotoxin concentration. Endotoxin ...

    • Manufacturer for LAL reagent manufacturer - Rapid Gel Clot single test kit – Bioendo

      Manufacturer for LAL reagent manufacturer - Ra...

      Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit) 1. Product Information Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures ...

    • Discountable price Endotoxin Microbiology - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo

      Discountable price Endotoxin Microbiology - Py...

      Pyrogen-free Microplates, 96 Well Plate Strips and pyrogen free Reagent Reservoir 1. Product information These pyrogen-free 96-well plates (endotoxin-free microplates, pyrogen-free reservoir, cell culture plate, endotoxin-free plates) is used in the End-point Chromogenic Lyophilized Amebocyte Lysate Assay, Kinetic Chromogenic Lyophilized Amebocyte Lysate Assay and Kinetic Turbidimetric  endotoxin test assay. The microplates and resevoirs contain endotoxins <0.005 EU/ml endotoxin. Catalog...

    • Super Lowest Price Endotoxin Free Microplate - Pyrogen-free (Endotoxin-free) Tris Buffer – Bioendo

      Super Lowest Price Endotoxin Free Microplate -...

      Pyrogen-free (Endotoxin-free) Tris Buffer 1. Product information Buffers must be validated to be free of detectable endotoxin andinterfering factors. Using 50mM Tris buffer to dissolve or dilute the testsamples is a convenient way to adjust the reaction pH. Pyrogen-free (endotoxin-free) Tris buffer to adjusting the pH of the LAL endotoxin test samples. Lyophilized Amebocyte Lysate testing microbiology detection of endotoxin by horseshoecrab blue blood lysate require certain conditions. The ...

    • 2022 China New Design LAL test for endotoxin - Endotoxin-free Glass Test Tubes – Bioendo

      2022 China New Design LAL test for endotoxin -...

      Endotoxin-free Glass Test Tubes   1. Product Information Endotoxin-free glass test tubes contain less than 0.005EU/ml endotoxin. Catalog number T107505 and T107540  are recommended for use as reaction tubes in gel clot and end-point chromogenic assays. Catalog number T1310018 and T1310005 is recommended for dilution of endotoxin standards and test samples. T1050005C is a special designed short endotoxin reaction tube that allows the pipette tips reaches the tube bottom. T087565 is used ...