We normally think and practice corresponding on the change of circumstance, and grow up. We aim at the achievement of a richer mind and body and also the living for Endotoxin Indicator For Depyrogenation, Endotoxin Gel Clot, Endotoxin Quantification Kit, If possible, please send your requirements with a detailed list including the style/item and quantity you require. We will then send our best prices to you.
New Arrival China Kinetic Turbidimetric Method endotoxin - Kinetic Turbidimetric Amebocyte Lysate Vial – Bioendo Detail:

Kinetic Turbidimetric Amebocyte Lysate Vial

1. Product Introduction

Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration. 

2. Product Parameter:

Assay range:0.005-50EU/ml; 0.01 – 10EU/ml

3. Product Application

End-product endotoxin (pyrogen) qualification, Water for injection endotoxin assay, raw material endotoxin testing or endotoxin level monitoring during manufacturing process for pharmaceutical companies or medical devices manufacturers.

Note:

Lyophilized Amebocyte Lysate reagent manufactured by Bioendo is made from amebocyte lysate from the horseshoe crab (Tachypleus tridentatus).

Catalog No.

ml/vial

Tests/Vial

Vials/Pack

Sensitivity EU/ml

KT17

1.7

16

10

0.01-10EU/ml

KT17S

 1.7

 16

 10

0.005-5EU/ml, 0.01-10EU/ml

KT52

5.2

50

10 

0.01-10EU/ml

KT52S

 5.2

 50

10 

0.005-5EU/ml, 0.01-10EU/ml

 

Product Condition:

The Lyophilized Amebocyte Lysate reagent sensitivity and the Control Standard Endotoxin potency are assayedagainst USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come withproduct instruction, Certificate of Analysis.


Product detail pictures:

New Arrival China Kinetic Turbidimetric Method endotoxin - Kinetic Turbidimetric Amebocyte Lysate Vial – Bioendo detail pictures

New Arrival China Kinetic Turbidimetric Method endotoxin - Kinetic Turbidimetric Amebocyte Lysate Vial – Bioendo detail pictures

New Arrival China Kinetic Turbidimetric Method endotoxin - Kinetic Turbidimetric Amebocyte Lysate Vial – Bioendo detail pictures


Related Product Guide:

With our excellent administration, potent technical capability and strict top quality control technique, we go on to provide our consumers with trusted quality, reasonable price ranges and fantastic providers. We intention at becoming one among your most trusted partners and earning your fulfillment for New Arrival China Kinetic Turbidimetric Method endotoxin - Kinetic Turbidimetric Amebocyte Lysate Vial – Bioendo , The product will supply to all over the world, such as: Doha, Sacramento, Guatemala, We'd like to invite customers from abroad to discuss business with us. We can provide our clients with high quality products and excellent service. We are sure that we will have good cooperative relationships and make a brilliant future for both parties.
  • Wide range, good quality, reasonable prices and good service, advanced equipment, excellent talents and continuously strengthened technology forces,a nice business partner.
    5 Stars By Ricardo from Montpellier - 2017.09.30 16:36
    This is a honest and trustworthy company, technology and equipment are very advanced and the prodduct is very adequate, there is no worry in the suppliment.
    5 Stars By Miguel from Italy - 2017.09.29 11:19

    Leave Your Messages

    Related products

    • Hot-selling Pipette tip supplier - Rapid Gel Clot single test kit – Bioendo

      Hot-selling Pipette tip supplier - Rapid Gel C...

      Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit) 1. Product Information Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures ...

    • OEM Manufacturer BET Test Procedure - Rapid Gel Clot 10 Samples Kit – Bioendo

      OEM Manufacturer BET Test Procedure - Rapid Ge...

      Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit) 1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedure...

    • Factory Free sample Coagulation Gel - Mini Dry Heat Incubator – Bioendo

      Factory Free sample Coagulation Gel - Mini Dry...

      Dry heat incubator single module 1. Product information  The Mini Dry Heat Incubator is a micro-processor controlled heating block with semi conductor heating technology.It adapts onboard use, smart, light and convenient for movement, suit for any kind of occasions. Especially good for the incubation of the gel clot LAL assay, LAL chromogenic endpoint assay incubation. 2. Product features 1. Unique designed. Smart and light, convenient movement, suit for various occasions. 2. LCD simultaneou...

    • Top Suppliers Endotoxin LAL Test Kit - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo

      Top Suppliers Endotoxin LAL Test Kit - Pyrogen...

      Pyrogen-free Microplates, 96 Well Plate Strips and pyrogen free Reagent Reservoir 1. Product information These pyrogen-free 96-well plates (endotoxin-free microplates, pyrogen-free reservoir, cell culture plate, endotoxin-free plates) is used in the End-point Chromogenic Lyophilized Amebocyte Lysate Assay, Kinetic Chromogenic Lyophilized Amebocyte Lysate Assay and Kinetic Turbidimetric  endotoxin test assay. The microplates and resevoirs contain endotoxins <0.005 EU/ml endotoxin. Catalog ...

    • Ordinary Discount Endotoxin Detection Kits - Endotoxin-free Glass Test Tubes – Bioendo

      Ordinary Discount Endotoxin Detection Kits - E...

      Endotoxin-free Glass Test Tubes   1. Product Information Endotoxin-free glass test tubes contain less than 0.005EU/ml endotoxin. Catalog number T107505 and T107540  are recommended for use as reaction tubes in gel clot and end-point chromogenic assays. Catalog number T1310018 and T1310005 is recommended for dilution of endotoxin standards and test samples. T1050005C is a special designed short endotoxin reaction tube that allows the pipette tips reaches the tube bottom. T087565 is used ...

    • Well-designed Bacterial Endotoxin Calculation - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo

      Well-designed Bacterial Endotoxin Calculation -...

      Beta-glucans Blocker for Blocking Beta Glucan Pathway 1. Product information There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Gl...