Newly Arrival Endotoxin Quantification Kit - LAL Reagent Water (Water for Bacterial Endotoxins Test) – Bioendo


Product Detail

Related Video

Feedback (2)

With our abundant experience and considerate products and services, we have been recognized to be a reputable supplier for a lot of global consumers for limulus amebocyte lysate, LAL endotoxin kit, Turbidimetric LAL assay, Standing still today and looking into the future, we sincerely welcome customers all over the world to cooperate with us.
Newly Arrival Endotoxin Quantification Kit - LAL Reagent Water (Water for Bacterial Endotoxins Test) – Bioendo Detail:

LAL Reagent Water ( Water for Bacterial Endotoxins Test / Water for BET / TAL Reagnt Water ) 

1. Product Information

LAL Reagent Water (Water for Bacterial Endotoxins Test or BET Water or Water for BET is specially processed super-purified endotoxin free water is used for Endotoxin test. Its endotoxin concentration is less than 0.005 EU/ml. Various packages, such as 2ml, 10ml, 50ml, 100ml and 500ml per unit, are provided for users’ convenience. LAL Reagent Water (Water for BET) could be used to dilute the assay sample, construct the stand curve, or reconstitute the Lyophilized Amebocyte Lysate reagents. 

2. Product Parameter

Endotoxin level: ≤0.005 EU/ml

Water for Bacterial Endotoxins Test is specially processed water is used for endotoxin detection. Its endotoxin concentration is less than 0.005EU/ml. We also provide water for BET with endotoxin level less than 0.001EU/ml for the assay sensitivity 0.001 to 5EU/ml kinetic chromogenic assay.

 

3. Product Features and Application

Endotoxin Free Water (Water for BET, LAL Reagent water, Endotoxin free water or BET water) is specially processed water intended for reconstitution of Lyophilized Amebocyte Lysate and Control Standard Endotoxin (CSE), and to dilute samples and control standards in the endotoxin assay operation.

For reconstitution of Lyophilized Amebocyte Lysate or Amebocyte Lysate, dilution of the test samples and Control Standard Endotoxin, preparation endotoxin free buffers, and construction of the standard curve. 500ml BET water main apply in extract endotoxins from medical devices. 

Catalog No.

Volume (ml/vial)

Package

TRW02

2ml in Ampoule

In Ampoule, 10 Ampoules/Pack

TRW05

5ml in Ampoule

 In Ampoule, 10 Ampoules/Pack

TRW10

10ml in Ampoule

 In Ampoule, 10 Ampoules/Pack

TRW50

50ml in Glass Vial

In Glass Vial, 10 Vials/Pack

TRW100

100ml in Glass Vial

 In Glass Vial, 10 Vials/Pack

TRW500

500ml in Glass Bottle

1 Vial

Product Condition

The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis.

What is BET water (bacterial endotoxin test water)?

Bacterial endotoxin test water that is endotoxin free level water, it mainly use for endotoxin test assay in the operation of reconstitution and dilution.

Such as, reconstitute lyophilized lysate reagent, control standard endotoxin dilution reconstitution and dilution, and samples dilutions.

Bioendo BET water (Water for BET) can be named TAL reagent water or LAL reagent water. LAL (lyophilized amebocyte lysate).


Product detail pictures:

Newly Arrival Endotoxin Quantification Kit - LAL Reagent Water (Water for Bacterial Endotoxins Test) – Bioendo detail pictures

Newly Arrival Endotoxin Quantification Kit - LAL Reagent Water (Water for Bacterial Endotoxins Test) – Bioendo detail pictures

Newly Arrival Endotoxin Quantification Kit - LAL Reagent Water (Water for Bacterial Endotoxins Test) – Bioendo detail pictures


Related Product Guide:

We not only will try our greatest to offer you excellent services to just about every client, but also are ready to receive any suggestion offered by our buyers for Newly Arrival Endotoxin Quantification Kit - LAL Reagent Water (Water for Bacterial Endotoxins Test) – Bioendo , The product will supply to all over the world, such as: Algeria, Mozambique, Honduras, We're your reliable partner in the international markets of our products and solutions. We focus on providing service for our clients as a key element in strengthening our long-term relationships. The continual availability of high grade solutions in combination with our excellent pre- and after-sales service ensures strong competitiveness in an increasingly globalized market. We're willing to cooperate with business friends from at home and abroad, to create a great future. Welcome to Visit our factory. Looking forward to have win-win cooperation with you.
  • It is really lucky to meet such a good supplier, this is our most satisfied cooperation, I think we will work again!
    5 Stars By Jeff Wolfe from Germany - 2017.10.13 10:47
    Factory equipment is advanced in the industry and the product is fine workmanship, moreover the price is very cheap, value for money!
    5 Stars By Karen from Guatemala - 2018.09.23 17:37

    Leave Your Messages

    Related products

    • China Factory for Endotoxin Analysis Methods - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo

      China Factory for Endotoxin Analysis Methods -...

      Beta-glucans Blocker for Blocking Beta Glucan Pathway 1. Product information There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Gl...

    • China Cheap price LAL gel clot method - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo

      China Cheap price LAL gel clot method - Gel Cl...

      Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule 1. Product Information Gel Clot Lyophilized Amebocyte Lysate Single Test in ampoule Contain endotoxin-specific Amebocyte Lysate which includes beta-glucan inhibitor in the formulation and will not react to beta-glucan. For our Single Test in glass ampoule, you could add sample to the glass ampoules directly. This means you don’t need to reconstitute Amebocyte Lysate at first, and you will decide how many tests use each time to avoi...

    • Europe style for BET Bacterial Endotoxin Test - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo

      Europe style for BET Bacterial Endotoxin Test -...

      Beta-glucans Blocker for Blocking Beta Glucan Pathway 1. Product information There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Gl...

    • Best quality LAL chromogenic detection - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo

      Best quality LAL chromogenic detection - Bioen...

      Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) 1. Product Information In Bioendo KC Endotoxin Test Kit, Amebocyte Lysate is co-lyophilized with chromogenic substrate. Therefore, bacterial endotoxin could be quantified based on the chromogenic reaction. The assay is strong resistance to interference, and has advantages of kinetic turbidimetric and end-point chromogenic method. Bioendo Endotoxin Test Kit contains Chromogenic Amebocyte Lysate, Reconstitution Buffer, CSE, Water for BE...

    • Discountable price Endotoxin Microbiology - Control Standard Endotoxin (CSE) – Bioendo

      Discountable price Endotoxin Microbiology - Co...

      Control Standard Endotoxin (CSE) 1. Product Information Control Standard Endotoxin (CSE) is extracted from E.coli O111:B4. CSE is an economic alternative to Reference Standard Endotoxin (RSE) in constructing standard curves, validating product and preparing controls in Lyophilized Amebocyte Lysate test. The labeled potency of CSE endotoxinE.coli standard is referenced against RSE. The Control Standard Endotoxin could be used with gel clot assay, kinetic turbidimetric assay or kinetic chromog...

    • Good Quality Gel Clot Assay - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo

      Good Quality Gel Clot Assay - Gel Clot Lyophil...

      Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule 1. Product Information Gel Clot Lyophilized Amebocyte Lysate Single Test in ampoule Contain endotoxin-specific Amebocyte Lysate which includes beta-glucan inhibitor in the formulation and will not react to beta-glucan. For our Single Test in glass ampoule, you could add sample to the glass ampoules directly. This means you don’t need to reconstitute Amebocyte Lysate at first, and you will decide how many tests use each time to avoi...