New Product Launching ” micro kinetic chromogenic endotoxin test kit ”

New product launching " micro kinetic chromogenic endotoxin test kit " 

 

Our company (Xiamen Bioendo Technology Co., Ltd) in order to better protect the Tachypleus tridentatus resources, meet the demand of our customers for endotoxin detection, and further improve the level of quantitative detection of endotoxin in China, our company provides higher sensitivity and linear range. A new generation of micro-kinetic chromogenic endotoxin detection reagent micro KCA with wider width and more accurate detection results. Provide comprehensive endotoxin detection solutions for drug testing units, pharmaceutical companies, medical device manufacturers, biotechnology companies and clinical diagnostic fields.

 

New Launching:

Micro kinetic chromogenic endotoxin test kit

According to Chinese Pharmacopoeia Chapter 1143 Bacterial Endotoxin Detection Method, the micro kinetic chromogenic endotoxin test kit mKC is prepared by kinetic chromogenic micro-technology, matched with pyrogen-free 96-well micro-detection plate/8-well strip, can be used for rapid detection of microorganisms in lysate test is High-throughput micro-quantitative endotoxin detection on the system ELx808IULALXH. Each test only needs 25μl of the test substance and 25μl of Lysate reagent, with strong anti-interference ability. It is recommended for endotoxin testing of samples such as vaccines, antibodies and biological products.

 

Catalog numbers for optional: 

Catalog No.

Description

Kit Contents

Sensitivity EU/ml

MKC0505VS

Bioendo™ KC Endotoxin Test Kit (Micro Kinetic Chromogenic Assay), 90 Tests/Kit

5 Chromogenic Amebocyte Lysate, 0.5ml (18 Tests/Vial);

5 Reconstitution Buffer, 2.0ml/vial; 

0.005 to 5EU/ml

MKC0505V

0.01 to 10EU/ml

MKC0505AS

Bioendo™ KC Endotoxin Test Kit (Micro Kinetic Chromogenic Assay), 90 Tests/Kit

5 Chromogenic Amebocyte Lysate, 0.5ml (18 Tests/ampoule);

5 Reconstitution Buffer, 2.0ml/vial; 

0.005 to 5EU/ml

MKC0505A

0.01 to 10EU/ml

MPMC96

8 wells per strip

96 wells per microplate, 12pcs detachable strips.

 

Micro KC Operational Benefits and Product Features:

● Saving resources, the amount of Lysate reagent resources used is one-eighth of the conventional kinetic chromogenic method, and the sample volume is only 25μl;

● Cost-effective, quantitative method performance, gel method cost. Compared with the dedicated micro-plates already on the market, we additionally offer a cost-saving detachable 8-well micro-plate reaction strip (Cat. No.: MPMC96);

● Compared with similar products on the market (such as sensitivity only up to 10-0.01EU/ml), this product has stronger anti-interference ability, higher sensitivity, better linearity of the standard curve, better detection repeatability, wider detection range, and higher sensitivity Optional 5-0.005EU/ml or 10-0.01EU/ml. Special test products need higher sensitivity Lysate reagent to solve experimental interference, we can provide the sensitivity up to 0.001EU/ml;

● Equipped with stable and reliable bacterial endotoxin quantitative detection equipment, such as ELx808IULALXH.

 

Recommendation microplate reader Solution A: Endootoxin Assay Rapid Microbiological Detection System

220524.5

It is equipped with BIOENDO & Biotek's Endotoxin Assay Rapid Microbiological Detection System ELx808IULALXH, and uses a bacterial endotoxin micro-detection reaction plate specially customized for micro KC to meet the requirements of the Chinese Pharmacopoeia bacterial endotoxin inspection method. The detection system provides 3Q validation to ensure the accuracy and reliability of the experimental results.

Features:

  • The wavelength range is 340-900nm, which can be used for ultraviolet detection and visible light detection;
  • 6-bit filter wheel, standard configuration includes 5 filters (340, 405, 490, 540 and 630nm) to meet all the requirements of the spectrophotometric method included in chapter 1143 of the Chinese Pharmacopoeia;
  • 4-Zone™ temperature control system (patented), the temperature control can reach 50℃, and the temperature accuracy is 0.1℃, which is suitable for quantitative detection of endotoxin;
  • The detection sensitivity of bacterial endotoxin can reach 0.001EU/ml, and the detection sensitivity of fungal (1,3)-β-D-glucose can reach 5pg/ml;
  • Precise optical path system, automatic incubator and temperature control module ensure that the ELx808IULALXH rapid detection system for Limulus test microorganisms can output accurate quantitative detection results of bacterial endotoxin.

 

Expansion of the micro KC system -

Improve bacterial endotoxin testing efficiency through automation 

The current challenge for endotoxin testing is to ensure consistent, reliable, and traceable results. Manual operation is difficult to maintain consistent results. Incorrect pipetting techniques and different operator habits will affect the experimental results, and the data is difficult to trace.

The BIOENDO “ FeiBao” automatic endotoxin detection system developed by Xiamen Bioendo Technology is committed to reducing human interference factors in the endotoxin detection process, realizing standardized and automated operations, and improving the repeatability, precision and data integrity of the detection. The system can perform high-throughput rapid detection, and is suitable for automatic and rapid detection of endotoxins in the fields of drug testing, scientific research and clinical diagnosis.

Features:

  • High-throughput, multi-functional, intelligent robotic arm with better stability and long life;
  • Flexible sample detection module;
  • Intelligent AI system, excellent performance, optional security version system;
  • It can be matched with absorbable light detector, fluorescence detector, etc.;
  • Precise micro sample adding system;
  • It is equipped with our powerful bacterial endotoxin detection software system.

 


Post time: Mar-20-2022