It adheres for the tenet "Honest, industrious, enterprising, innovative" to develop new products and solutions continuously. It regards shoppers, success as its individual success. Let us produce prosperous future hand in hand for limulus amoebocyte lysate LAL test, Bacterial Endotoxin Test Procedure, Endotoxin indicator vial, We welcome customers, business associations and friends from all parts of the world to contact us and seek cooperation for mutual benefits.
OEM Manufacturer BET Test Procedure - Compact Modular Dry Heat Incubator – Bioendo Detail:

Dry Heat Incubator

1. Product description:

Dry Heat Incubator TAL-M2 is amicroprocessor-controlled device, high precision of temperature control, samplepreparation parallelism, as an alternative to the traditional water bathdevice. It is recommended to use in the gel clot TAL endotoxin assay. And it can be widely used in various other application includes the pharmaceutical, chemical, food safety, environment, quality inspection. TAL-M2 includes 2 heating modules. TAL- M2 A Dry bath incubator Can achieve two independent heating modules, thermostats, unique combo designed to meet the needs of more experimental.

2. Product features

1, LCD display, simple interface.

2, high heating speed, uniformheating, accurate temperature control, high stability, low energy consumptionand no noise.

3, Built in temperature calibrationfunction, automatic fault detection and buzzer alarm function.

4, Built in over-temperatureprotection device, safe and reliable use, prolong the service life of themachine.

5, product design, compact and tight,small occupied space, freer and easier.

6, Various blocks for convenientreplacement, cleaning and disinfection.

7,It Can achieve two independentheating modules, thermostats, unique combo designed to meet the needs of moreexperimental.

dry bath double control, dry incubator doublemodule, limulus polyphemus blue blood, tal kinetic chromogenic method, talendotoxin kit

Product Name & Descriptions

TAL-M2 Dry heat incubator

(single heating module);

One modular total 60 holes for mass test in pharmaceuticals application.

Temperature control Range Ambient+5℃ ~ 150℃
Temperature setting range Ambient+5℃ ~ 150℃
Temperature rising time ≤ 30min (from 20℃ rise to 150℃), rise to 37deg C in about 60s.
Temperature Stability @100~150℃ ≤±1℃
Temperature Stability @40~100℃ ≤±0.5℃
Temperature Uniformity @40℃ ±0.3℃
Modular temperature uniformity ±0.5℃
Displayed Temperature Precision 0.1℃
Temperature Control time 99h59min
Fuse protector 250v, 3A/6A, Φ5×20
Highest Temperature 150℃
Power supply AC220V/AC110V, 50/60Hz, 400W
Dimension D260*W220*H95mm

 


Product detail pictures:

OEM Manufacturer BET Test Procedure - Compact Modular Dry Heat Incubator – Bioendo detail pictures

OEM Manufacturer BET Test Procedure - Compact Modular Dry Heat Incubator – Bioendo detail pictures

OEM Manufacturer BET Test Procedure - Compact Modular Dry Heat Incubator – Bioendo detail pictures


Related Product Guide:

We know that we only thrive if we can guarantee our combined rate competiveness and good quality advantageous at the same time for OEM Manufacturer BET Test Procedure - Compact Modular Dry Heat Incubator – Bioendo , The product will supply to all over the world, such as: Uruguay, Brazil, Czech, When you are keen on any of our items following you view our product list, please feel free to make contact with us for inquiries. You'll be able to send us emails and get in touch with us for consultation and we shall respond to you as soon as we are able to. If it's convenient, you could find out our address in our web site and come to our enterprise. or additional information of our items by yourself. We're generally ready to build lengthy and steady co-operation relations with any possible shoppers within the associated fields.
  • With a positive attitude of "regard the market, regard the custom, regard the science", the company works actively to do research and development. Hope we have a future business relationships and achieving mutual success.
    5 Stars By King from Spain - 2017.12.09 14:01
    It can be said that this is a best producer we encountered in China in this industry, we feel lucky to work with so excellent manufacturer.
    5 Stars By Quyen Staten from Ethiopia - 2017.04.08 14:55

    Leave Your Messages

    Related products

    • Hot sale Endpoint Chromogenic Endotoxin test kit - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo

      Hot sale Endpoint Chromogenic Endotoxin test ki...

      Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) 1. Product Information In Bioendo KC Endotoxin Test Kit, Amebocyte Lysate is co-lyophilized with chromogenic substrate. Therefore, bacterial endotoxin could be quantified based on the chromogenic reaction. The assay is strong resistance to interference, and has advantages of kinetic turbidimetric and end-point chromogenic method. Bioendo Endotoxin Test Kit contains Chromogenic Amebocyte Lysate, Reconstitution Buffer, CSE, Water for BE...

    • New Delivery for Biochemical Nature Of Bacterial Endotoxin Is - Control Standard Endotoxin (CSE) – Bioendo

      New Delivery for Biochemical Nature Of Bacteria...

      Control Standard Endotoxin (CSE) 1. Product Information Control Standard Endotoxin (CSE) is extracted from E.coli O111:B4. CSE is an economic alternative to Reference Standard Endotoxin (RSE) in constructing standard curves, validating product and preparing controls in Lyophilized Amebocyte Lysate test. The labeled potency of CSE endotoxinE.coli standard is referenced against RSE. The Control Standard Endotoxin could be used with gel clot assay, kinetic turbidimetric assay or kinetic chromog...

    • 8 Year Exporter Endotoxin LAL Test - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo

      8 Year Exporter Endotoxin LAL Test - Pyrogen-f...

      Pyrogen-free Microplates, 96 Well Plate Strips and pyrogen free Reagent Reservoir 1. Product information These pyrogen-free 96-well plates (endotoxin-free microplates, pyrogen-free reservoir, cell culture plate, endotoxin-free plates) is used in the End-point Chromogenic Lyophilized Amebocyte Lysate Assay, Kinetic Chromogenic Lyophilized Amebocyte Lysate Assay and Kinetic Turbidimetric  endotoxin test assay. The microplates and resevoirs contain endotoxins <0.005 EU/ml endotoxin. Catalog...

    • Short Lead Time for Endotoxin Assay LAL - LAL Reagent Water (Water for Bacterial Endotoxins Test) – Bioendo

      Short Lead Time for Endotoxin Assay LAL - LAL ...

      LAL Reagent Water ( Water for Bacterial Endotoxins Test / Water for BET / TAL Reagnt Water )  1. Product Information LAL Reagent Water (Water for Bacterial Endotoxins Test or BET Water or Water for BET )is specially processed super-purified endotoxin free water is used for Endotoxin test. Its endotoxin concentration is less than 0.005 EU/ml. Various packages, such as 2ml, 10ml, 50ml, 100ml and 500ml per unit, are provided for users’ convenience. LAL Reagent Water (Water for BET) could...

    • Factory source Advantage Of LAL Test - Rapid Gel Clot single test kit – Bioendo

      Factory source Advantage Of LAL Test - Rapid G...

      Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit) 1. Product Information Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures ...

    • High reputation 1000ul Pipette tip box - Single-Channel Mechanical Pipettor – Bioendo

      High reputation 1000ul Pipette tip box - Singl...

      Single-Channel Mechanical Pipettor   1. Product Information Single channel mechanical pipette is ideal tool to support endotoxin detection with Lyophilized Amebocyte Lysate which covers gel-clot technique, kinetic turbidimetric technique, kinetic chromogenic technique, and end-point chromogenic technique. All pipettors are produced by following ISO8655 – 2:2002. The quality control involves gravimetric testing of each pipette with distilled water at 22℃.   2. Product Features: - ...