OEM Manufacturer Endotoxin Assay Kit - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo


Product Detail

Related Video

Feedback (2)

Our well-equipped facilities and excellent excellent management throughout all stages of creation enables us to guarantee total buyer satisfaction for Bacterial Endotoxin Test Usp 85, Pyrogen free microplate, Turbidimetric endotoxin assays, We welcome new and outdated clients from all walks of daily life to get hold of us for long term organization associations and achieving mutual results!
OEM Manufacturer Endotoxin Assay Kit - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo Detail:

 Endotoxin Challenge Vials (Endotoxin Indicator)

 

1. Product Information

The Endotoxin Challenge Vial (ECV,Endotoxin Indicator) is used in the validation of dry heat depyrogenation cycles. Endotoxin Challenge Vials are placed in the cold spots of the dry heat oven. After cycle completion, the log reduction in endotoxin levels can be determined by comparing the endotoxin levels in the baked vs not baked Endotoxin Indicators. The Endotoxin Challenge vials are designed to indicate a minimum 3-log reduction in endotoxin content when tested using gel clot endotoxin assay kit, kinetic turbidimetric endotoxin assay kit or chromogenic Lyophilized Amebocyte Lysate assay kits. Endotoxin Challenge Vial contains 1000 to 10000EU Endotoxins level in a glass vial. ECV1250V and ECV2500V are sealed in vials that configurate the heat resistant stoppers and heat resistant labels, which could be placed in dry-heat oven or dry-heat tunnel without removal of stoppers and caps(lid).

Validation of dry heat sterilization cycle(s) is required by regulations of ANSI, AAMI, ISO, USP and FDA to ensure that all items that are required to be sterile or endotoxin-free are able to consistently and reliably be sterilized to reduce the chance of introducing or spreading an infectious micro-organism or pyrogens.

Follow the Regulations requirement, use Bioendo ECV is able to operate the endotoxin free validation or pyrogen free validation. More important information is Bioendo ECV no need rubber lid(cap) removal in the heating operation.

 

2. Product Parameter

The potency: 1000 to 10000 EU per vial and 2000 to 10000 EU in a vial.  

 

3. Product Features and Application

In vial with heat resistant stopper (tolerable high temperature up to 360 Celsius degree) and heat resistant label. 

In the procedure of baking or drying, ECV vial’s lid no need to remove. 

Without excipient.  

Endotoxin Challenge Vial  (10ml glass bottle and 2ml of ISO standard 2R glass bottle)

Catalog No.

Endotoxins Level (EU/vial)

Package

ECV1250V

1000-10000

In Vial, 10 Vials/Pack

ECV1250VR

 1000-10000

ISO 2R vial, 10 Vials/Pack

ECV2500V

2000-10000

In Vial, 10 Vials/Pack

ECV2500VR

 2000-10000

ISO 2R vial, 10 Vials/Pack

ECV100000V

50000-200000

In Vial, 10 Vials/Pack

How is the features of Bioendo’s Endotoxin Challenge Vails (Endotoxin Indicator)?

Endotoxin challenge vial, in the operation procedures, the lysate reagent has to match the ECV kit, and no need remove the lit during the baking procedure.


Product detail pictures:

OEM Manufacturer Endotoxin Assay Kit - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo detail pictures

OEM Manufacturer Endotoxin Assay Kit - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo detail pictures

OEM Manufacturer Endotoxin Assay Kit - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo detail pictures

OEM Manufacturer Endotoxin Assay Kit - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo detail pictures


Related Product Guide:

We're commitment to offer you the competitive price ,remarkable products excellent, also as fast delivery for OEM Manufacturer Endotoxin Assay Kit - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo , The product will supply to all over the world, such as: Jamaica, Ukraine, Norwegian, Nowadays our products sell all over the domestic and abroad thanks for the regular and new customers support. We provide high quality product and competitive price, welcome the regular and new customers cooperate with us!
  • The factory technical staff not only have high level of technology, their English level is also very good, this is a great help to technology communication.
    5 Stars By Anne from Oman - 2017.08.18 11:04
    The company comply with the contract strict, a very reputable manufacturers, worthy a long-term cooperation.
    5 Stars By Salome from Naples - 2017.11.29 11:09

    Leave Your Messages

    Related products

    • 2022 Good Quality Kinetic Chromogenic Endotoxin test kit - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo

      2022 Good Quality Kinetic Chromogenic Endotoxin...

      Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) 1. Product Information In Bioendo KC Endotoxin Test Kit, Amebocyte Lysate is co-lyophilized with chromogenic substrate. Therefore, bacterial endotoxin could be quantified based on the chromogenic reaction. The assay is strong resistance to interference, and has advantages of kinetic turbidimetric and end-point chromogenic method. Bioendo Endotoxin Test Kit contains Chromogenic Amebocyte Lysate, Reconstitution Buffer, CSE, Water for BE...

    • Manufacturing Companies for Bacteria Endotoxin Test - Control Standard Endotoxin (CSE) – Bioendo

      Manufacturing Companies for Bacteria Endotoxin ...

      Control Standard Endotoxin (CSE) 1. Product Information Control Standard Endotoxin (CSE) is extracted from E.coli O111:B4. CSE is an economic alternative to Reference Standard Endotoxin (RSE) in constructing standard curves, validating product and preparing controls in Lyophilized Amebocyte Lysate test. The labeled potency of CSE endotoxinE.coli standard is referenced against RSE. The Control Standard Endotoxin could be used with gel clot assay, kinetic turbidimetric assay or kinetic chromog...

    • New Arrival China Endotoxin Indicator - Pyrogen-free Pipette tips and Consumables – Bioendo

      New Arrival China Endotoxin Indicator - Pyroge...

      Pyrogen-free Pipette tips and tip box 1. Product information We offer various low endotoxin, pyrogen-free accessories,includes Water for Bacterial Endotoxins Test, endotoxin-free test tubes, pyrogen-free pipette tips, pyroegn-free microplates for your operation. High quality depyrogenated and low endotoxin level consumables to ensure the success of your endotoxin assays. Pyrogen-free pipette tips are certified to contain <0.001 EU/ml endotoxin. The tips allow more flexibility with diffe...

    • Well-designed Bacterial Endotoxin Calculation - Pyrogen-free (Endotoxin-free) Tris Buffer – Bioendo

      Well-designed Bacterial Endotoxin Calculation -...

      Pyrogen-free (Endotoxin-free) Tris Buffer 1. Product information Buffers must be validated to be free of detectable endotoxin andinterfering factors. Using 50mM Tris buffer to dissolve or dilute the testsamples is a convenient way to adjust the reaction pH. Pyrogen-free (endotoxin-free) Tris buffer to adjusting the pH of the LAL endotoxin test samples. Lyophilized Amebocyte Lysate testing microbiology detection of endotoxin by horseshoecrab blue blood lysate require certain conditions. The ...

    • Wholesale Kinetic Turbidimetric TAL Test - Kinetic Turbidimetric Amebocyte Lysate Vial – Bioendo

      Wholesale Kinetic Turbidimetric TAL Test - Kin...

      Kinetic Turbidimetric Amebocyte Lysate Vial 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration.  2. Product Parame...

    • Low price for Bacterial Endotoxin Test Kinetic Turbidimetric Method – Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo

      Low price for Bacterial Endotoxin Test Kinetic ...

      Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration. T...