Our business promises all users of the first-class items and the most satisfying post-sale company. We warmly welcome our regular and new prospects to join us for Bacterial Endotoxin Test Validation, limulus amebocyte, Bacterial Endotoxin Test Kinetic Turbidimetric Method, The team of our company along with the use of cutting-edge technologies delivers impeccable top quality products supremely adored and appreciated by our shoppers worldwide.
OEM/ODM China Kinetic Turbidimetric Method of endotoxin testing - Kinetic Turbidimetric Amebocyte Lysate Vial – Bioendo Detail:

Kinetic Turbidimetric Amebocyte Lysate Vial

1. Product Introduction

Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration. 

2. Product Parameter:

Assay range:0.005-50EU/ml; 0.01 – 10EU/ml

3. Product Application

End-product endotoxin (pyrogen) qualification, Water for injection endotoxin assay, raw material endotoxin testing or endotoxin level monitoring during manufacturing process for pharmaceutical companies or medical devices manufacturers.

Note:

Lyophilized Amebocyte Lysate reagent manufactured by Bioendo is made from amebocyte lysate from the horseshoe crab (Tachypleus tridentatus).

Catalog No.

ml/vial

Tests/Vial

Vials/Pack

Sensitivity EU/ml

KT17

1.7

16

10

0.01-10EU/ml

KT17S

 1.7

 16

 10

0.005-5EU/ml, 0.01-10EU/ml

KT52

5.2

50

10 

0.01-10EU/ml

KT52S

 5.2

 50

10 

0.005-5EU/ml, 0.01-10EU/ml

 

Product Condition:

The Lyophilized Amebocyte Lysate reagent sensitivity and the Control Standard Endotoxin potency are assayedagainst USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come withproduct instruction, Certificate of Analysis.


Product detail pictures:

OEM/ODM China Kinetic Turbidimetric Method of endotoxin testing - Kinetic Turbidimetric Amebocyte Lysate Vial – Bioendo detail pictures

OEM/ODM China Kinetic Turbidimetric Method of endotoxin testing - Kinetic Turbidimetric Amebocyte Lysate Vial – Bioendo detail pictures

OEM/ODM China Kinetic Turbidimetric Method of endotoxin testing - Kinetic Turbidimetric Amebocyte Lysate Vial – Bioendo detail pictures


Related Product Guide:

Now we have highly developed devices. Our items are exported towards the USA, the UK and so on, enjoying a great popularity among the customers for OEM/ODM China Kinetic Turbidimetric Method of endotoxin testing - Kinetic Turbidimetric Amebocyte Lysate Vial – Bioendo , The product will supply to all over the world, such as: Nepal, The Swiss, Zurich, We are proud to supply our products and solutions to every costumer all around the world with our flexible, fast efficient services and strictest quality control standard which has always approved and praised by customers.
  • Product variety is complete, good quality and inexpensive, the delivery is fast and transport is security, very good, we are happy to cooperate with a reputable company!
    5 Stars By Gemma from French - 2018.09.23 18:44
    The company has a good reputation in this industry, and finally it tured out that choose them is a good choice.
    5 Stars By Janet from Rotterdam - 2017.06.22 12:49

    Leave Your Messages

    Related products

    • Hot-selling Control Standard Endotoxin Definition - LAL Reagent Water (Water for Bacterial Endotoxins Test) – Bioendo

      Hot-selling Control Standard Endotoxin Definiti...

      LAL Reagent Water ( Water for Bacterial Endotoxins Test / Water for BET / TAL Reagnt Water )  1. Product Information LAL Reagent Water (Water for Bacterial Endotoxins Test or BET Water or Water for BET )is specially processed super-purified endotoxin free water is used for Endotoxin test. Its endotoxin concentration is less than 0.005 EU/ml. Various packages, such as 2ml, 10ml, 50ml, 100ml and 500ml per unit, are provided for users’ convenience. LAL Reagent Water (Water for BET) could...

    • Rapid Delivery for Endotoxin Producing Bacteria - Control Standard Endotoxin (CSE) – Bioendo

      Rapid Delivery for Endotoxin Producing Bacteria...

      Control Standard Endotoxin (CSE) 1. Product Information Control Standard Endotoxin (CSE) is extracted from E.coli O111:B4. CSE is an economic alternative to Reference Standard Endotoxin (RSE) in constructing standard curves, validating product and preparing controls in Lyophilized Amebocyte Lysate test. The labeled potency of CSE endotoxinE.coli standard is referenced against RSE. The Control Standard Endotoxin could be used with gel clot assay, kinetic turbidimetric assay or kinetic chromog...

    • Factory wholesale Depyrogenated microplate - Nymph X Water Purification System – Bioendo

      Factory wholesale Depyrogenated microplate - N...

      NYMPHX Nymph X Water Purification System   Nymph X Water Purification System could transfer tap water into pure water and ultrapure water. Equipped with a pressure stabilizer and low flow-rate operating mode, the system can adapt to various source conditions without any extra pre-treatment necessary. The system also supports multiple water dispensing modes, and the precision of quantitative and quality-controlled dispense of water could reach ±1%. Meanwhile, comprehensive monitoring could be...

    • Factory wholesale Endotoxin Free Microplates - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo

      Factory wholesale Endotoxin Free Microplates -...

       Endotoxin Challenge Vials (Endotoxin Indicator)   1. Product Information The Endotoxin Challenge Vial (ECV,Endotoxin Indicator) is used in the validation of dry heat depyrogenation cycles. Endotoxin Challenge Vials are placed in the cold spots of the dry heat oven. After cycle completion, the log reduction in endotoxin levels can be determined by comparing the endotoxin levels in the baked vs not baked Endotoxin Indicators. The Endotoxin Challenge vials are designed to indicate a minimum 3...

    • Wholesale Price China LAL test for pyrogens - Kinetic Incubating Microplate Reader ELX808IULALXH  – Bioendo

      Wholesale Price China LAL test for pyrogens - ...

      Kinetic Incubating Microplate Reader 1. Product information Kinetic Incubating Microplate Reader Elx808 is a multifunctional kinetic reader designed for bacterial endotoxin assay, fungi (1,3)-ß-D-glucan assay and ELISA assays. The reader is a highly accurate, easy to use instrument for kinetic turbidimetric LAL/TAL assay, kinetic chromogenic LAL test and endpoint chromogenic LAL assay.  Compare to kinetic incubating tube reader,the microplate reader is more efficient and is possible to be sc...

    • China New Product Endotoxin Bacteria - Pyrogen-free (Endotoxin-free) Tris Buffer – Bioendo

      China New Product Endotoxin Bacteria - Pyrogen...

      Pyrogen-free (Endotoxin-free) Tris Buffer 1. Product information Buffers must be validated to be free of detectable endotoxin andinterfering factors. Using 50mM Tris buffer to dissolve or dilute the testsamples is a convenient way to adjust the reaction pH. Pyrogen-free (endotoxin-free) Tris buffer to adjusting the pH of the LAL endotoxin test samples. Lyophilized Amebocyte Lysate testing microbiology detection of endotoxin by horseshoecrab blue blood lysate require certain conditions. The ...