Our organization sticks to your principle of "Quality may be the life of your organization, and reputation will be the soul of it" for Chromogenic endotoxin test, Endotoxin Determination, Endotoxin LAL Test Kit, Standing still today and looking into the future, we sincerely welcome customers all over the world to cooperate with us.
Special Price for Endotoxin Detection Test Is Based On - Endotoxin-free Glass Test Tubes – Bioendo Detail:

Endotoxin-free Glass Test Tubes

 

1. Product Information

Endotoxin-free glass test tubes contain less than 0.005EU/ml endotoxin. Catalog number T107505 and T107540  are recommended for use as reaction tubes in gel clot and end-point chromogenic assays. Catalog number T1310018 and T1310005 is recommended for dilution of endotoxin standards and test samples. T1050005C is a special designed short endotoxin reaction tube that allows the pipette tips reaches the tube bottom. T087565 is used for kinetic tube reader.

 

2. Product Parameter

Endotoxin level ≤0.005EU/ml

3. Product Features and Application

Made with borosilicate glass. Cover with aluminum caps. Various size suitable for gel clot reactions, sample dilutions and control standard endotoxin dilutions.

 Catalog No.  

Size mm

(outside diameter)

With

Aluminum Caps

Package

tubes/pack

T087565

Φ8×75

No

65

T107505C

Φ10×75

Yes

5

T107540

 Φ10×75

No

40

T127505C

Φ12×75

Yes

5

T127525

 Φ12×75

No

25

T1310005C

Φ13×100

Yes

5

T1310018

 Φ13×100

No

18

Why would I use endotoxin-free test consumables?

such as endotoxin free tubes; pyrogen-free tips; pyrogen-free microplates; endotoxin free sample bottles; 

According to China Pharmacopoeia, the utensils needed in the procedure of endotoxin test assay, such as sample vessel, dilution and reaction tubes, pipette tips, have to choose endotoxin free consumables. the utensils needed for the experiment need to be processed to remove possible exogenous endotoxins. If the endotoxin is not removed, it will interfere with the result of endotoxin assay.

 


Product detail pictures:

Special Price for Endotoxin Detection Test Is Based On - Endotoxin-free Glass Test Tubes – Bioendo detail pictures

Special Price for Endotoxin Detection Test Is Based On - Endotoxin-free Glass Test Tubes – Bioendo detail pictures

Special Price for Endotoxin Detection Test Is Based On - Endotoxin-free Glass Test Tubes – Bioendo detail pictures


Related Product Guide:

We rely upon strategic thinking, constant modernisation in all segments, technological advances and of course upon our employees that directly participate inside our success for Special Price for Endotoxin Detection Test Is Based On - Endotoxin-free Glass Test Tubes – Bioendo , The product will supply to all over the world, such as: Angola, Mali, Italy, We expect to provide products and services to more users in global aftermarket markets; we launched our global branding strategy by providing our excellent products all over the world by virtue of our well reputed partners letting global users keep pace with technology innovation and achievements with us.
  • We have been engaged in this industry for many years, we appreciate the work attitude and production capacity of the company, this is a reputable and professional manufacturer.
    5 Stars By Jacqueline from Vietnam - 2017.08.21 14:13
    The factory technical staff not only have high level of technology, their English level is also very good, this is a great help to technology communication.
    5 Stars By Octavia from Sevilla - 2018.12.28 15:18

    Leave Your Messages

    Related products

    • Factory wholesale Kinetic Turbidimetric LAL Assay - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo

      Factory wholesale Kinetic Turbidimetric LAL Ass...

      Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration. T...

    • New Arrival China Dry heat tunnel validation by ECV - Single-Channel Mechanical Pipettes (Semi-sterile) – Bioendo

      New Arrival China Dry heat tunnel validation by...

      Single-Channel Mechanical Pipettes (Semi-sterile)   1. Product Information The Single-Channel Mechanical Pipettes (Semi-sterile) is adjustable, which could be used to dispense liquid precisely. Measuring volume of our Single-Channel Mechanical Pipettes (Semi-sterile) ranges from 0.1μL to 5mL. Products are produced based on ISO8655/DIN12650. It could be widely employed on endotoxin detection, etc..   2. Product Features - Light weight, economic - The pipettes cover volume range from 0.1μL to 5...

    • Factory wholesale Kinetic chromogenic LAL test - Endpoint Chromogenic Kit EC64405 – Bioendo

      Factory wholesale Kinetic chromogenic LAL test ...

      End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) 1. Product Information End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is conducted by adding a colorless artificial peptide substrate solution into mixture of Lyophilized Amebocyte Lysate and test sample after a certain incubation period. If test sample contain endotoxin, a yellow color will develop in the 96 well microplate. Its absorbance (λmax = 405nm) is related to the endotoxin concentration. Endotoxin ...

    • Hot sale Endpoint Chromogenic Endotoxin test kit - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo

      Hot sale Endpoint Chromogenic Endotoxin test ki...

      Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) 1. Product Information In Bioendo KC Endotoxin Test Kit, Amebocyte Lysate is co-lyophilized with chromogenic substrate. Therefore, bacterial endotoxin could be quantified based on the chromogenic reaction. The assay is strong resistance to interference, and has advantages of kinetic turbidimetric and end-point chromogenic method. Bioendo Endotoxin Test Kit contains Chromogenic Amebocyte Lysate, Reconstitution Buffer, CSE, Water for BE...

    • Top Quality Endotoxin - Depyrogenated Sample Bottles ( Endotoxin Free ) – Bioendo

      Top Quality Endotoxin - Depyrogenated Sample B...

      Depyrogenated Sample Container 1. Product information We offer various of low endotoxin, pyrogen free accessories products,includes Water for Bacterial Endotoxins Test, pyrogen-free test tubes, pyrogen-free pipettor tips, microplates and sample bottles for your conveniences. High quality depyrogenated low endotoxin pyrogen free products insure the success of your experiments. Depyrogenated (Endotoxin Free) Sample container(endotoxin free bottle, pyrogen free bottle, pyrogen free sample bot...

    • Factory wholesale TAL Reagent Water - Pyrogen-free Centrifuge Tube – Bioendo

      Factory wholesale TAL Reagent Water - Pyrogen-...

      Pyrogen-free Centrifuge Tube   Product features: * Pyrogen-free Centrifuge tube is made from virgin polypropylene to meet the general requirements of the laboratory. * Pyrogen-free, Endotoxin level <0.005EU/ml * High strength non-toxic materials * Printed clear graduations with marking area * Gamma Radiation Sterilized * 50ml Maximum RCF is 18000g, 15ml Maximum RCF is 12000g * DNase/RNase free * Autoclavable * Temperature range is -20°C to 121°C * Leak-proof * Cap 50% longer ideal for avo...