Wholesale Price Endotoxin Gel Clot Test Kit - Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial – Bioendo


Product Detail

Related Video

Feedback (2)

Every single member from our large efficiency profits team values customers' requirements and organization communication for Pyrogen Free Tube, Detection Of Endotoxin, Bacterial Endotoxin Limit For API, We are also constantly looking to establish relationship with new suppliers to provide innovative and smart solution to our valued customers.
Wholesale Price Endotoxin Gel Clot Test Kit - Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial – Bioendo Detail:

Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial

1. Product Information

Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial Contain endotoxin-specific Amebocyte Lysate which includes beta-glucan inhibitor in the formulation and will not react to beta-glucan. For our Single Test in Vial, you could add sample to the vial directly. This means you don’t need to reconstitute Amebocyte Lysate at first, and you will decide how many vials use each time to avoid waste. Endotoxin free tube for dilution of CSE is necessary. Operation of endotoxin detection by choice of Bioendo Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial conforms to the USP, the EP.

2. Product Parameter

Gel clot assay single test glass vial

Sensitivities:  0.03EU/ml, 0.06EU/ml, 0.125EU/ml, 0.25 EU/ml

3.Product Feature and Application

Single step endotoxin detection,

without expensive endotoxin assay instruments,

Suitable for end-product endotoxin testing before product released,

Product sensitivity standardized according to US Pharmacopoeia criterion and China Pharmacopoeia criterion.

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from lysate of amebocytes (white blood cells) from the horseshoe crab.

Catalog number Sensitivity (EU/ml) (IU/ml) Tests/Vial Vials/Pack
G020015 0.015 1 50
G020030 0.03 1 50
G020060 0.06 1 50
G020125 0.125 1 50
G020250 0.25 1 50
G020500 0.5 1 50

Product Condition

The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis.

Why the most selected gel clot assay kit G02:

1. The most economical and commonly used test reagent for endotoxin detection.

2. Single test in a vial for one stepping reduce the risk of contamination.

3. Gel clot assay single test glass vial no need sophisticated microplate reader.

4. Saving endotoxin free tube when using G02 series to test endotoxins in the procedure of endotoxin test assay’s operation.

Related products in the endotoxin test assay:
Water for Bacterial Endotoxins Test (BET),  Recommend TRW50 or TRW100
Endotoxin free glass tube ( dilution tube ),  Recommend T1310018
Pyrogen free tips,  Recommend PT25096 or PT100096
Pipettor, Recommend PSB0220
Test Tube Rack,
Incubation Instrument (Water Bath or Dry Heat Incubator ), Recommend Dry Heat Incubator TAL-M2
Vortex Mixter, Recommend VXH.
Control Standard Endotoxin, CSE10V.

Product detail pictures:

Wholesale Price Endotoxin Gel Clot Test Kit - Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial – Bioendo detail pictures

Wholesale Price Endotoxin Gel Clot Test Kit - Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial – Bioendo detail pictures

Wholesale Price Endotoxin Gel Clot Test Kit - Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial – Bioendo detail pictures

Wholesale Price Endotoxin Gel Clot Test Kit - Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial – Bioendo detail pictures

Wholesale Price Endotoxin Gel Clot Test Kit - Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial – Bioendo detail pictures

Wholesale Price Endotoxin Gel Clot Test Kit - Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial – Bioendo detail pictures


Related Product Guide:

We constantly carry out our spirit of ''Innovation bringing advancement, Highly-quality guaranteeing subsistence, Administration selling advantage, Credit rating attracting buyers for Wholesale Price Endotoxin Gel Clot Test Kit - Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial – Bioendo , The product will supply to all over the world, such as: Victoria, Angola, Austria, We've been always creating new technology to streamline the production, and give products with competitive prices and high quality! Customer satisfaction is our priority! You can let us know your idea to develop unique design for your own model to prevent too much similar parts in the market! We are going to present our best service to satisfy all your needs! Remember to contact us right away!
  • The factory workers have rich industry knowledge and operational experience, we learned a lot in working with them,we are extremely grateful that we can encount a good company has excellent wokers.
    5 Stars By Griselda from Indonesia - 2017.09.29 11:19
    The sales person is professional and responsible, warm and polite, we had a pleasant conversation and no language barriers on communication.
    5 Stars By Marina from Serbia - 2017.07.07 13:00

    Leave Your Messages

    Related products

    • Factory Supply Endotoxin Free Water - Endotoxin-free Glass Test Tubes – Bioendo

      Factory Supply Endotoxin Free Water - Endotoxi...

      Endotoxin-free Glass Test Tubes   1. Product Information Endotoxin-free glass test tubes contain less than 0.005EU/ml endotoxin. Catalog number T107505 and T107540  are recommended for use as reaction tubes in gel clot and end-point chromogenic assays. Catalog number T1310018 and T1310005 is recommended for dilution of endotoxin standards and test samples. T1050005C is a special designed short endotoxin reaction tube that allows the pipette tips reaches the tube bottom. T087565 is used ...

    • China wholesale Chromogenic endotoxin detection - Endpoint Chromogenic Kit EC80545 – Bioendo

      China wholesale Chromogenic endotoxin detection...

      Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) 1. Product Information Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) provides a fast measurement for endotoxin quantification. The endotoxin in the sample activates a cascade of enzymes in Amebocyte Lysate, the activated enzyme splits the synthetic substrate, releasing a yellow-colored item. Then the yellow item can further react with diazo reagents to form purple items with maximum abso...

    • Well-designed Bacterial Endotoxin Calculation - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo

      Well-designed Bacterial Endotoxin Calculation -...

      Beta-glucans Blocker for Blocking Beta Glucan Pathway 1. Product information There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Gl...

    • PriceList for LAL Method - Compact Modular Dry Heat Incubator – Bioendo

      PriceList for LAL Method - Compact Modular Dry...

      Dry Heat Incubator 1. Product description: Dry Heat Incubator TAL-M2 is amicroprocessor-controlled device, high precision of temperature control, samplepreparation parallelism, as an alternative to the traditional water bathdevice. It is recommended to use in the gel clot TAL endotoxin assay. And it can be widely used in various other application includes the pharmaceutical, chemical, food safety, environment, quality inspection. TAL-M2 includes 2 heating modules. TAL- M2 A Dry bath incubat...

    • Factory source Advantage Of LAL Test - Single-Channel Mechanical Pipettor – Bioendo

      Factory source Advantage Of LAL Test - Single-...

      Single-Channel Mechanical Pipettor   1. Product Information Single channel mechanical pipette is ideal tool to support endotoxin detection with Lyophilized Amebocyte Lysate which covers gel-clot technique, kinetic turbidimetric technique, kinetic chromogenic technique, and end-point chromogenic technique. All pipettors are produced by following ISO8655 – 2:2002. The quality control involves gravimetric testing of each pipette with distilled water at 22℃.   2. Product Features: - ...

    • Good quality Turbidimetric LAL test - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo

      Good quality Turbidimetric LAL test - Bioendo ...

      Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration. T...